EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
500 Paper Exit
263
Confidential
4.8.3 CHUTE UP EXIT, CHUTE LOW EXIT
Removal
1.
Remove the COVER REAR 500. (p.270)
2.
Remove the COVER REAR. (p.167)
3.
Remove the COVER LEFT. (p.169)
4.
Remove the COVER RIGHT. (p.168)
5.
Remove the COVER EXIT 500. (p.261)
6.
Remove the 500 EXIT ASSY. (p.262)
7.
Remove the two screws (gold, tapping, 8mm) securing the CHUTE UP EXIT to
the CHUTE LOW EXIT.
8.
Separate the CHUTE UP EXIT and CHUTE LOW EXIT.
Figure 4- 74. CHUTE UP EXIT, CHUTE LOW EXIT Removal
CHUTE UP EXIT
(SEE Note1)
CHUTE LOW EXIT
CHUTE UP EXIT
Figure1
Figure2
LINK GATE OCT
8)
7)