EPSON EPL-N3000/AcuLaser M4000N
Revision C
Disassembly and Assembly
Option 550 Paper Feeder
318
Confidential
4.11.14 CLUTCH ASSY PH
Removal
1.
Remove the 550 FEEDER OPTION. (p.311)
2.
Remove the six screws (gold, tapping, 8mm) securing the PLATE TIE.
3.
Remove the PLATE TIE from the CHUTE OUT.
4.
Disconnect the connector (P/J853) of the CLUTCH ASSY PH from the
HARNESS ASSY CLSNR1.
5.
Remove the E-ring retaining the CLUTCH ASSY PH and remove the CLUTCH
ASSY PH from the SHAFT FEED.
Installation
1.
Install the CLUTCH ASSY PH to the SHAFT FEED, and secure it with the E ring.
2.
Connect the connector (P/J853) of the CLUTCH ASSY PH to the HARNESS
ASSY CLSNR1.
3.
Install the PLATE TIE to the CHUTE OUT with the six screws (gold, tapping,
8mm).
4.
Install the 550 FEEDER OPTION. (p.311)
Figure 4- 122. CLUTCH ASSY PH Removal
C A U T I O N
When installing it, match the notch of the CLUTCH ASSY PH
to the boss of the CHUTE OUT.
Carefully route the harness of the CLUTCH ASSY PH.
C A U T I O N
Place the connected connector between the ribs of the CHUTE
OUT.
JG3515AA
CHUTE OUT
CLUTCH ASSY PH
PLATE TIE
Note 1)
CONNECTOR
CHUTE OUT
WHEN ASSEMBLING
5)
4)
3)
2)
Содержание AcuLaser M4000N
Страница 1: ...EPSON EPL N3000 AcuLaserM4000N A4 Monochrome Laser Printer SERVICE MANUAL SEPG03004 Confidential ...
Страница 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 404: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 408: ...Confidential C H A P T E R 7 APPENDIX ...