4.5.1 150 FEEDER ASSY
Removal
1.
Remove the COVER REAR 500. (p.270)
2.
Remove the FUSER ASSY. (p.253)
3.
Remove the COVER REAR. (p.167)
4.
Remove the FAN MAIN. (p.293)
5.
With the BTR ASSY installed, remove the CHUTE TRANSFER.
(p.258)
6.
Disconnect the connector (P/J245) of the HARNESS ASSY TRAY1 from the
HARNESS ASSY CHUTE.
7.
Remove the five screws (sliver, with collars, with spring washers, 8mm) securing
the 150 FEEDER ASSY to the printer body.
8.
Shift the 150 FEEDER ASSY to the rear, and disengage the boss on the right side
of the 150 FEEDER ASSY from the frame.
9.
Lift the 150 FEEDER ASSY in the direction of the arrow (A), and disengage the
boss on the left side of the 150 FEEDER ASSY.
10. Remove the 150 FEEDER ASSY from the printer body.
Figure 4- 39. 150 FEEDER ASSY Removal
C H E C K
P O I N T
Disassembly procedures for this part are different between EPL-
N3000 and AcuLaser M4000N. For AcuLaser M4000N, see
4.14.3
150 FEEDER ASSY (AcuLaser M4000N)
(p.382)
.
C H E C K
P O I N T
The FEEDER ASSY clicks midway when lifted, but lift it by
application of slight force.
JG3148AB
(A)
150 FEEDER ASSY
9)
6)
9)
8)
7)
10)
Содержание AcuLaser M4000N
Страница 1: ...EPSON EPL N3000 AcuLaserM4000N A4 Monochrome Laser Printer SERVICE MANUAL SEPG03004 Confidential ...
Страница 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 404: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 408: ...Confidential C H A P T E R 7 APPENDIX ...