EPSON AcuLaser C2000
Revision C
Disassembly and Assembly
Disassembling Procedure
136
4.2.10 Fusing Pressure Motor Removal
1.
Remove the PU1 Support Board. (See “PU1 Support Plate Removal”
on page -135.)
2.
Remove the harnesses from the connectors on the Fusing Pressure
Motor.
3.
Remove 4 screws securing the Fusing Pressure Motor Support Board
to the printer frame and the grounding screw.
4.
Remove 2 screws securing the Fusing Pressure Motor, and remove
the Fusing Pressure Motor.
Figure 4-27. Fusing Pressure Motor Removal
4.2.11 Fan Motor Removal
4.2.11.1 Power Supply Fan Motor Removal
1.
Remove the Rear Controller Cover. (See “Rear Controller Cover
Removal” on page -126.)
2.
Remove the Rear Right Cover. (See “Rear Right Cover Removal” on
page -127.)
3.
Free the harness from 5 harness clamps.
4.
Disconnect the power supply fan motor harness and remove 2 long
screws securing the Power Supply Fan Motor, and remove the Power
Supply Fan Motor.
Figure 4-28. Power Supply Cooling Fan Motor Removal
Содержание AcuLaser Color 2000
Страница 11: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Страница 56: ...EPSON AcuLaser C2000 Revision C Product Descriptions Handling Precautions 56 ...
Страница 57: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 93: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 97: ...EPSON AcuLaser C2000 Revision C Troubleshooting Troubleshooting Method 97 Figure 3 1 Print Pattern ...
Страница 119: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 162: ...C H A P T E R 5 ADJUSTMENT ...
Страница 164: ...C H A P T E R 6 MAINTENANCE ...
Страница 166: ...C H A P T E R 7 APPENDIX ...
Страница 170: ......
Страница 171: ......
Страница 198: ......
Страница 199: ......
Страница 200: ......
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......