4.2.9 Transfer Motor Removal
4.2.9.1 PU1 Support Plate Removal
1.
Remove the Rear Controller Cover. (See “Rear Controller Cover
Removal” on page -126.)
2.
Remove the Rear Cover. (See “Rear Cover Removal” on page -127.)
3.
Remove 5 harnesses connecting to the PU1 from the connectors. (See
“PU1 (Power Supply Board) Removal” on page -132.)
4.
Remove 4 screws securing the PU1 Support Plate and remove the
PU1 Support Board.
Figure 4-25. PU1 Support Plate Removal
4.2.9.2 Transfer Motor Removal
1.
Remove the PU1 Support Board. (See “PU1 Support Plate Removal”
on page -135.)
2.
Remove the transfer motor connector and 4 screws securing the
Transfer Motor, and remove the Transfer Motor.
Figure 4-26. Transfer Motor Removal
dis20
Содержание AcuLaser Color 2000
Страница 11: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Страница 56: ...EPSON AcuLaser C2000 Revision C Product Descriptions Handling Precautions 56 ...
Страница 57: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 93: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 97: ...EPSON AcuLaser C2000 Revision C Troubleshooting Troubleshooting Method 97 Figure 3 1 Print Pattern ...
Страница 119: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 162: ...C H A P T E R 5 ADJUSTMENT ...
Страница 164: ...C H A P T E R 6 MAINTENANCE ...
Страница 166: ...C H A P T E R 7 APPENDIX ...
Страница 170: ......
Страница 171: ......
Страница 198: ......
Страница 199: ......
Страница 200: ......
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......