EPSON AcuLaser C2000
Revision C
Disassembly and Assembly
Disassembling Procedure
143
4.2.17 Transfer Mechanism
4.2.17.1 Timing Roller Solenoid Removal
1.
Remove the Rear Controller Cover. (See “Rear Controller Cover
Removal” on page -126.)
2.
Remove the Rear Cover. (See “Rear Cover Removal” on page -127.)
3.
Remove the PU1 Support Plate. (See “PU1 Support Plate Removal”
on page -135.)
4.
Remove the harness of the Timing Roller Solenoid from the MCU
connector.
5.
Remove 1 screw securing the Timing Roller Solenoid to the main
frame.
Figure 4-39. Timing Roller Solenoid Removal
4.2.17.2 Middle Roller Solenoid Removal
1.
Remove the Rear Controller Cover. (See “Rear Controller Cover
Removal” on page -126.)
2.
Remove the Rear Cover. (See “Rear Cover Removal” on page -127.)
3.
Remove the PWB-A Support Plate. (See “MCU (PWB-A Board)
Removal” on page -131.)
4.
Remove the connector of the Middle Roller Solenoid and 1 screw.
Figure 4-40. Middle Roller Solenoid Removal
Содержание AcuLaser Color 2000
Страница 11: ...C H A P T E R 1 PRODUCTDESCRIPTIONS ...
Страница 56: ...EPSON AcuLaser C2000 Revision C Product Descriptions Handling Precautions 56 ...
Страница 57: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 93: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 97: ...EPSON AcuLaser C2000 Revision C Troubleshooting Troubleshooting Method 97 Figure 3 1 Print Pattern ...
Страница 119: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 162: ...C H A P T E R 5 ADJUSTMENT ...
Страница 164: ...C H A P T E R 6 MAINTENANCE ...
Страница 166: ...C H A P T E R 7 APPENDIX ...
Страница 170: ......
Страница 171: ......
Страница 198: ......
Страница 199: ......
Страница 200: ......
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......