6. Electrical connections
Danger!
Risk of electric shock. In the event of a faulty electrical installation,
there is a risk of electric shock (even after completion of the installation work).
The electrical installation may only be carried out by a qualified electrician.
The connections are made according to the connection diagram or according to the following
terminal diagrams - see Fig. 6 or Fig. 7.
Make the electrical connections as shown on the connection diagrams on pages 18 - 19.
The generator has a pre-mounted power supply cable with a Cekon type plug (16A or 32A). For
connection the appropriate socket with fuse protection has to be used.
The control unit is connected as shown in the connection diagram on pages 21-22.
In order to simplify the installation, the terminals are color-coded and numbered individually.
Connection terminals and power se-
lection switches (18 kW model).
6.1 SteamRock Basic 18 kW connec-
tion terminals
Pic. 6
Terminal
Marking
Description
1
L1
L1 phase
2
L1
(L4)
3
L2
L2 phase
4
L2
(L5)
5
L3
L3 phase
6
L3
(L6)
7
N
N
11
N
(N line 2)
15
PE
PE power supply
16
PE
(PE power supply 2)
21
N
N - control unit
22
S1
S1 - control unit
23
Wb
Steam on - control
24
PE
PE - control unit
25
N
Signal - output
26
A2
Signal - output
27
Fragrance
Fragrance
28
PE
PE - Fragrance
Terminal diagram for SteamRock Basic with 18 kW, 400 V con-
nection (3 x 32 A).