24
EN
6.4 SteamRock Basic connection to Econ S2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
N S1 Wb PE
N S1 Wb PE
L1 L2 L3 N N N N
PE
(Gr)
PE
(Gr)
L1 L1 L2 L2 L3 L3 N N N N N N N N
SteamRock Basic
9,0 kW (3 x 16 A)
SteamRock Basic
18,0 kW (3 x 32 A)
L1
L2
L3
N
PE (Gr)
400 V 3N 50 Hz AC
3 x 32 A + PE (Gr)
L1 L2 L3 N PE (Gr)
400 V 3N 50 Hz AC
3 x 16 A + PE (Gr)
N A2
PE (Gr)
FR
AGR
ANC
E
25 26 27 28
N A2
PE (Gr)
FR
AGR
ANC
E
PE (Gr)
S1
N
Wb
Übrige Anschlüsse gemäß Gebrauchsanleitung
Additional connections according to the user manual
ST2
ST1
Duftstoffbehälter
mit Sonden (optional)
Essence container with
level probes (optional)
PE (Gr)
S1
N
Wb
Übrige Anschlüsse gemäß Gebrauchsanleitung
Additional connections according to the user manual
ST2
ST1
Duftstoffbehälter
mit Sonden (optional)
Essence container with
level probes (optional)
Econ S2
Econ S2
PE
(Gr)
PE
(Gr)
Pay attention to provide the fuse protection on all power supply lines!
32A / 16A
N
L1
L3
L2
PE (Gr)
Pre-assembled Cekon plug power supply
400 V 3N AC - 32A / 16A
!
ATTENTION!
No external loads may be connected to
the main terminal block in the steam
generator! Risk of fire due to overload!