35
EN
Reason:
Water supply blocked.
Solution
: Check water supply. Check if the filter mesh at the water supply connec-
tor is blocked, clean if necessary.
Reason:
Water filling valve is blocked or faulty.
Solution
: Clean the valve (e.g. pressurized air) and make sure it is operational.
Reason:
Water level probe got stuck or is faulty.
Solution
: Make sure the float of the probe can move freely, clean if necessary and
check for functionality (see chapter installation > water level control for details).
Fault
:
No decaler liquid (also shown on the Econ S2 display)
Reason:
Descaler level low. Connection cable to level probe interrupted.
Solution
: Refill descaler (cleaner). Check the level probe and cable connections.
Restart the generator.
Fault
:
Thermo-fuse triggered (also shown on the Econ S2 display)
Reason:
Overheating in the water tank.
Solution
: See point #1 „overheating limiter fuse“. Restart the generator.
Fault
:
Steam outlet spits hot water.
Reason:
Water foaming.
Solution
: Check if the water may be foaming due to contamination with oils or
similar substances. Clean the tank if necessary.
Reason:
Steam pipe installed incorrectly, steam pipe blocked by condensed water.
Solution
: Make sure the steam pipe is not blocked by condensed water. If neces-
sary a syphon may need to be installed. Make sure the steam can go through the
pipe freely.
Reason:
Water level probe fault.
Solution
: Inspect the water level probe, clean if necessary. Make sure that the
float can move freely. See page 17 for details.
Fault
:
No steam produced (heating does not start)
Reason:
Overheating limiter fuse released.
Solution
: Overheating due to too low water level. Reset the limiter fuse by
pushing firmly on the reset button located on the bottom side of the generator
under the rubber cap (see page 12). Inspect the generator for possible reasons for
overheating. Attention! Allow min. 5 minutes to cool down the generator.
Fault
:
Status LED flashes continuously
Reason:
Incorrect configuration or setup (e.g. jumper JP1 or JP2 set incorrectly)
Solution
: Check the jumpers JP1, JP2 for correct position. Restart the generator.
Check connection to control unit.