40
Installation Instructions - Relay Box for Infrared Cabins
Installation
EN
3
Connect IR emitters to IR-1, IR-2 and IR-3 (
C
).
Use a plug-in module if you connect multiple IR emitters to one terminal.
See
Example – plug-in modules (optional),
The IR emitter lines must all have the same cross-section.
Observe the total output:
IR-1 max. 1.5 kW, IR-2 max. 1.5 kW, IR-3 max. 0.5 kW.
4
Connect the cabin lighting to the light (
A
) terminal.
5
Connect the main power supply to the mains (
B
) terminal.
6
Connect the power supply to the 24-V DC jack (
D
).
Do not establish a connection to the power supply until you have set
all switches. See 5.6 Setting the switches,
5.6 Setting the switches
Once the IR emitters are installed and connected, the jumpers for the type
of emitters and channel groups must be set. As a rule, the unit address for
the relay box must not be changed.
The cabin address must only be programmed if the installation is a multi-
cabin installation.
See 6.3 Programming the cabin address,
Setting the jumper for the type of IR emitters,
Setting channel groups for IR emitters,
Setting the jumper for the type of IR emitters
1
DANGER! Ensure that the IR relay box is current-free.
Open the housing as needed.