1

SMART

 

PROGRAMMABLE RELAYS

SERIES 900

INSTRUCTION MANUAL

LIFETIME WARRANTY

GUARANTEED SAME-DAY SHIPPING

ADVANTAGE PRICING

WE DIDN’T INVENT

CONTROL, 

WE’RE

PERFECTING IT.

Содержание 900 Series

Страница 1: ...Y GUARANTEED SAME DAY SHIPPING ADVANTAGE PRICING 1 SMART PROGRAMMABLE RELAYS SERIES 900 INSTRUCTION MANUAL LIFETIME WARRANTY GUARANTEED SAME DAY SHIPPING ADVANTAGE PRICING WE DIDN T INVENT CONTROL WE...

Страница 2: ...h can be used as digital inputs Ability to add up to three 3 expansion modules expanding I O s to 32 digital inputs 16 relay outputs Communication module allows programmable relay to be connected to a...

Страница 3: ...lso selects deselects links ESC This key is used to exit the menu or a selection During the parameter entry it proceeds to the next parameter without saving the changes ARROW On the program editor scr...

Страница 4: ...sent in the incoming power supply it may be necessary to insert an isolation transformer between the supply and the line terminals of the Series 900 relay 2 While using the DC Series 900 relay run the...

Страница 5: ...C2 AN AN 2 1 C1 6 5 INPUT 6 X DC AN1 AN2 0 10 V DC 12 24 V DC 6 5 4 2 1 3 4 2 1 I P O P 3 C A B 8 7 OP1 OP3 OP2 OP4 64 9mm 2 35 64 45mm 1 49 64 72mm 2 53 64 90 5mm 3 9 16 100mm 3 15 16 4 3mm 11 64 SEL...

Страница 6: ...not change the states of the inputs outputs and special functions and continues with the execution of the program When the cursor is on the PARAMETERS option and OK is pressed then screen 4 will be di...

Страница 7: ...r SOFT TEXT MESSAGES The Series 900 relay provides 16 soft text message blocks which can be used to display text messages the preset value and current value of any special function block or the curren...

Страница 8: ...splayed PROGRAM PROTECTION 1 If the password is already enabled and user attempts to gain access using wrong password then an error message is displayed 2 If four such consecutive attempts are made th...

Страница 9: ...RANSFER function allows data to be transferred from Memory Card to the Series 900 relay or vice versa Transferring data to the memory card is useful when the user wants to load the same program in man...

Страница 10: ...confirm the changes that have been made 14 Press Z3 to select STOPBIT and press ALT to edit 15 Using Up Z4 and Down Z2 keys select the number of stop bits 16 Press OK to confirm the changes that have...

Страница 11: ...clock date and time on the Series 900 relay CREATING A NEW PROGRAM Select File New from the menu bar to create a new program A blank screen will appear Now you can start entering the program Ensure th...

Страница 12: ...ectable as 1200 2400 4800 9600 baud PARITY Selectable as NONE EVEN and ODD STOP BIT Selectable as 1 and 2 Stop Bits CLOCK SETTING 1 Select the Transfer Device Clock menu command The Device Clock windo...

Страница 13: ...w and select Time Switch 1 1 2 Move the cursor to the Contact 1 column of the first row and left click on the block to place the Time Switch 3 Right click on the Time Switch and select properties to o...

Страница 14: ...indow and select I2 4 Move the cursor to the Contact 1 column of the second row and left click on the block to place the input Also place it in the Contact 1 column of the third row COUNTER SELECTION...

Страница 15: ...ximum Input Frequency Hz 10 5 10 5 Analog Inputs Number of Analog Inputs 2 NA 2 NA Input Range V 0 10V DC 10 bit resolution NA 0 10V DC 10 bit resolution NA Input Impedance W 8 NA 8 NA Maximum Input V...

Страница 16: ...ck feed delivery OTHER APPLICATIONS Solar electric systems Marine applications Harsh environments Display panels and traffic control signs APPLICATIONS ORDERING INFORMATION 900 SBA8I4OZC 900 SBA8I4OM...

Отзывы: