3.2 Communication functions
The KNX Home module provides the following communication functions.
The data type is defined by the KNX association.
Settings made using a setpoint enable changes during operation. The
actual value supplies current data from the cabin. A feedback mechanism
sends a signal when changes are made in the cabin.
No.
Name
Function
Data type
Selection
Setting
0
Cabin lighting
Switch
1 bit ON/OFF
Control > cabin light
On/Off or 0–100%
1
Sauna
Switch
1 bit ON/OFF
Control >
Temperature in the
sauna
On/Off or SET-
POINT
2
Vaporiser tank
Switch
1 bit ON/OFF
Control >
Vaporiser tank
On/Off or SET-
POINT
3
Light setpoint
Setpoint
1 byte
Control > cabin light
0–100%
4
Temperature setpoint
Setpoint
2 bytes
Control >
Temperature in the
sauna
SETPOINT
0–65,535
5
Humidity setpoint
Setpoint
2 bytes
Control >
Vaporiser tank
SETPOINT
0–65,535
6
Actual light value
Measurement
1 byte
Measurements > cabin
light
On/Off
7
Actual temperature value
Measurement
2 bytes
Measurements > Tem-
perature in the sauna
On/Off
8
Actual humidity value
Measurement
2 bytes
Measurements > Tem-
perature in the sauna
On/Off
9
Light feedback
Switch feedback
1 bit ON/OFF
Control > cabin light
On/Off or 0–100%
10
Sauna feedback
Switch feedback
1 bit ON/OFF
Control >
Temperature in the
sauna
On/Off or SET-
POINT
11
Vaporiser tank feedback
Switch feedback
1 bit ON/OFF
Control >
Vaporiser tank
On/Off or SET-
POINT
12
Potential-free contact
(PFC) switch
Switch
1 bit ON/OFF
Control >
Potential-free
contact
On/off
13
PFC feedback
Switch feedback
1 bit ON/OFF
Control >
Potential-free
contact
On/Off