background image

26

Installation and Operating Instructions - KNX Home-Modul 

General terms and conditions of service

EN

General terms and conditions of 

service 

(T&C, Dated 08-2018)

I. Scope

Unless otherwise agreed in writing for specific instances, these terms and 
conditions of service shall apply to service operations, including reviewing 
and remedying complaints. All our existing or future legal relationships 
shall be governed solely by the following terms and conditions of service.
We do not recognise any of the customer’s conflicting terms and condi-
tions unless we have given our express written consent to their applicabil-
ity. 
We hereby expressly object to any of the customer’s terms and conditions 
included in the customer’s General Terms and Conditions of Business or 
order confirmation. Unconditional acceptance of order acknowledgments 
or deliveries shall not be construed as any form of acknowledgment of 
such terms and conditions. Ancillary agreements or amendments must be 
confirmed in writing. 

II. Costs

The customer shall bear the following costs in connection with services 
rendered:

Mounting/dismantling and electrical (de-)installation

Transportation, postage and packaging

Function testing and troubleshooting, including inspection and repair 
costs

There shall be no third-party billing.

III. Performance and cooperation obligations

The customer shall provide assistance free of charge to the manufacturer in 
rendering services.
In the case of a warranty claim, the manufacturer shall provide replace-
ment parts necessary for servicing free of charge.

IV. Service visit by the manufacturer

Services rendered on site by an employee of the manufacturer must be 
agreed in advance.

Содержание SBM GLT KNX

Страница 1: ...Druck Nr 2934 5021 Stand 1 1 2019 EN Made in Germany SBM GLT KNX KNX Home Modul for building management systems Installation and Operating Instructions...

Страница 2: ...not permit ted Compensation will be claimed in the event of infringements All rights reserved with regard to patent claims or submission of design or utility patent Characters symbols and illustratio...

Страница 3: ...11 3 2 Communication functions 12 3 3 Sample installation 13 3 4 Circuit boards 14 4 Mounting and electrical installation 15 4 1 Mounting the KNX Home Modul 15 4 2 Connecting the KNX Home Modul with...

Страница 4: ...rselfwiththe following terms and symbols DANGER Danger Indicates a hazardous situation which if not avoided will result in death WARNING Warning Indicates a hazardous situation which if not avoided co...

Страница 5: ...erformed by a trained electrician from an authorised elec trical company Observe the stipulations in VDE 0100 part 701 The system must be disconnected and removed entirely from the mains supply before...

Страница 6: ...ating period must be set so that the heating switches off au tomatically after a specific period of time If the heating does not switch off automatically after a defined heating period cabin use must...

Страница 7: ...ehold and similar electrical appliances safety Part 2 30 Particular require ments for room heaters DIN EN 60335 2 53 Household and similar electrical appliances safety Part 2 53 Particular require men...

Страница 8: ...of the housing Nameplate example Requirements for operation and storage The KNX Home module must only be mounted outside of sauna cabins infrared cabins and steam rooms The mounting location must fulf...

Страница 9: ...higher EmoStyle i InfraStyle i software release R 3 44 or higher EmoTouch 3 also SteamRock Premium software release R 2 08 or higher Check the software release of your control unit Perform an update...

Страница 10: ...e module is connected for each cabin The KNX Home module transfers data between the sauna bus and the KNX bus in both directions Its use is configured using the building manage ment system The KNX Hom...

Страница 11: ...sed to establish a connection from the sauna bus to the KNX bus The plastic housing completely encloses the circuit boards Power is supplied via the bus line Top piece of KNX Home module A KNX circuit...

Страница 12: ...nt 1 byte Control cabin light 0 100 4 Temperature setpoint Setpoint 2 bytes Control Temperature in the sauna SETPOINT 0 65 535 5 Humidity setpoint Setpoint 2 bytes Control Vaporiser tank SETPOINT 0 65...

Страница 13: ...243 211 LE D 2mA rt S KHUAKE 010 10nF 50V 1uF 50V NC P4641H050T1G ADUM1251 AC PL214 PVL10 LTC 2862C S 8 1 S MBJ30C A S MBJ30C A 742792693 742792693 100nF 50V 210 A 111 03 ADUM5201W 1uF 50V NC P4641H03...

Страница 14: ...ls for KNX bus F KNX programming button C Lower circuit board for S bus connection G LEDs for S bus status display D S bus connection H Programming button for S bus cabin address 10 1 2 C31 R 8 R 14 C...

Страница 15: ...ome Modul Tools hardware Drill Wood screws 4 x 25 mm Mounting on a fixed wall Screws 4 x 25 mm and suitable anchors The KNX Home Modul is intended to be mounted on the outer wall of the cabin or in th...

Страница 16: ...iring the connections 1 Feed the connection cable through the opening on the top piece of the housing Upper piece of SBM GLT KNX housing 2 Plug the S bus line into the RJ12 jack 3 Plug the KNX lines i...

Страница 17: ...rews 4 2 Connecting the KNX Home Modul with the S bus On the circuit board of the relay box or add on module you will find 2 connection jacks for the S bus lines Four connection jacks are provided wit...

Страница 18: ...S bus plug in module The S bus address of the cabin to be controlled must be configured in the KNX Home Modul 4 2 1 Connecting the S bus cable to the relay box or module NOTICE Incorrect data transfe...

Страница 19: ...e circuit board entirely from the mains supply 2 Remove the housing cover 3 Plug the plug into an S bus jack on the circuit board Circuit board sections for S bus jacks 4 Replace the housing cover on...

Страница 20: ...ice b Press twice for cabin 3 The LED flashes three times c Press three times for cabin 4 The LED flashes four times d Press four times for cabin 5 The LED flashes five times e Press five times for ca...

Страница 21: ...address 1 Press the KNX programming button Programming mode is activated The programming LED lights up 2 Load the physical address into the KNX Home Modul 3 Load the user software into the KNX Home Mo...

Страница 22: ...essing and holding until the code entry is displayed a Emotec Press and hold the jog dial b InfraStyle InfraStyle i Press and hold the Enter icon 2 Enter code 5349 and confirm Increase or decrease the...

Страница 23: ...KNX Home Modul Installation and Operating Instructions 23 Mounting and electrical installation 3 Select and confirm 4 Select and confirm C Home 11 51 HRPH KNX 10 25...

Страница 24: ...munication When the building management system and the KNX Home Modul are connected you must define the transfer protocol Familiarity with the gen eral operating functions is assumed Configuring the t...

Страница 25: ...e KNX Enable checkbox You are not required to set any further values for the KNX transfer protocol 6 Confirm your setting with Enable ONE NONE 1200 19200 Enable 30 Disable TWO ODD 2400 38400 Disable E...

Страница 26: ...Conditions of Business or order confirmation Unconditional acceptance of order acknowledgments or deliveries shall not be construed as any form of acknowledgment of such terms and conditions Ancillary...

Страница 27: ...services shall be performed only if proof of purchase of the equipment can be presented Any and all warranty claims shall become void if modifications are made to the equipment without the manufacture...

Страница 28: ...KNX Home Modul General terms and conditions of service EN The manufacturer s General Terms and Conditions of Business in the ver sion available at www eos sauna com agb shall apply in addition to the...

Страница 29: ...stic foil Electronic waste Electronic waste must be disposed of at the designated local collection point for electronic waste Electrical devices that are no longer needed must be recycled at a recycli...

Страница 30: ...30 Installation and Operating Instructions KNX Home Modul EN...

Страница 31: ...KNX Home Modul Installation and Operating Instructions 31...

Страница 32: ...uctions in a safe place Please always provide us with nameplate data such as model item num ber and serial number so we can provide fast and efficient support Date of sale Stamp retailer signature EOS...

Отзывы: