Error Messages & Troubleshooting
=
interrupted room sensor circuit.
The temperature sensor (KTY) is
faulty, or the line to the temperature
sensor is interrupted.
=
short-circuit in the sensor circuit
temperature sensor (KTY) is
faulty, or the line to the temper-
ature sensor has a short circuit.
Error message
Error message (only in connection with SteamRock Basic steam generator)
Possible fault
Remedy
Arrange for a specialist to
check the lines and sensor.
The sensor at 20°C has ap-
prox. 1.9 k
W,
replace if nec-
essary.
Arrange for a specialist to
check the lines and the sen-
sor.
The control continuously monitors the temperature sensor as well as the connected steam gener-
ator (Steamtec II Basic only). Following are the possible error messages:
12:00
=
Water tank filling error
(steam generator)
12:00
=
Draining error
(steam generator)
12:00
=
Steam generator error
12:00
=
Overheating error
12:00
=
Essence container empty
Check the water supply to
steam generator. Check the
water filling valve.
Check the drain of the
steam generator (e.g. may
be blocked by scale debris).
Clean if necessary.
Faulty connection to steam
generator. Check if steam
generator is switched on.
Check connection cables.
Refill the container with es-
sence for steam rooms.
12:00
Sensor -
break
12:00
Sensor short
-circuit