Operation details
Essence dosing function becomes active if one
of the two following conditions are met:
1. The steam room has reached the set point
temperature and the control is in usual
regulation phase.
2. The steam room is since at least 30 min-
utes in active heating mode.
The essence injection will only take place if
there was steam production after the previous
essence injection. Otherwise there will be no
essence injection during the present cycle.
This prevents that an excessive quantity of es-
sences collects in the steam pipe because the
steam room has reached the set point tem-
perature and there is no steam production (no
steam flow in the steam pipeline).
Essence dosing adjustment
The dosing intervals may be adjusted in 1 min-
ute steps within a 1 to 30 minutes range.
Setting the dosing intervals to “0” will switch
the essence dosing off.
Dosing
interval, min.
Injection
duration, sec.
Essence quantity
per cycle (grams)*
1
1
0,5 -1
1
3
3
1
5
5 - 6
1
7
7 - 8
1
10
11 - 12
1
15
17 - 19
*For EOS dosing pump, depending on the position of the rotation rolls
Injection duration per cycle is set during initial setup
of the control unit (see page 19).
!
AtteNtioN!
Do not use essences which may present
a health risk by high concentration. use
only special essences for steam rooms.
Essence dosing intervals
12:00
30°C
30
6:00
- - : - -
Temperature
Fragrance
Auto-Stop
Start time
MODE
12:00
30°C
30
6:00
- - : - -
Temperature
Fragrance
Auto-Stop
Start time
MODE
12:00
30°C
30
6:00
- - : - -
Temperature
Fragrance
Auto-Stop
Start time
During Stand-by
Adjustment range:
1 - 30 minutes
MODE
12:00
30°C
30
6:00
- - : - -
Temperature
Fragrance
Auto-Stop
Start time
12:00
30°C
10
6:00
- - : - -
Temperature
Fragrance
Auto-Stop
Start time
> 3 sec.
During active heating
In the same way as described above but with
the inverted interface.