20
EN
12:00
12:00
1
12:00
12:00
3
12:00
> 3 Sec
MODE
> 3 Sec
MODE
range 0 - 2
range 1 - 5 K
12:00
10
> 3 Sec
MODE
range 0-15 s
(default 0)
You can set the hysteresis from 1K to 5K in order
to adjust the temperature regulation and opti-
mize steam production.
Use “down” button to change value and press
“mode” button for 3 seconds to confirm.
Default value is 3K.
This setting adjusts the
essence injection du-
ration
and thus allows you to set the essence
quantity per each injection.
For instance the setting “10” means the dosing
pump will run for 10 seconds per injection.
You can make the setting from 1 to 15 sec.
After this the setup is complete and the
control unit will switch to the regular stand-by
interface.
Set the fan operation mode by selecting the
setting value from 0 to 2.
0 = fan disabled during heating, fan will run only af-
ter the heating (cabin dry cycle)
1 = fan is on during steam off intervals (active heat-
ing) + fan runs after heating (cabin dry program)
2 = fan is always on if heating is on, + fan runs after
heating (cabin dry cycle)
Press “mode” for 3 sec to confirm setting.
Fan setting
Hysteresis setting
Essence dosing setting
12:00
Temperature
30°C
Fragrance
30
Auto-Stop
6:00
Start time
- - : - -