Heating time limitation
The heating time limitation can be adjusted with the JP5 jumper position on the main board of
the control unit. You can set the limitation to 6 hours, 12 hours or set the heating time to unlimited
(manual) mode. The JP5 jumper is located in the middle at the upper edge of the board. You will
need tweezers or an alike tool to change the jumper position. Alternatively you can also take the
board out of the housing slightly (undo the mounting screws in the corners).
If set to unlimited position („24“) with the heating time can be progrmmed up to 23:59 or also set
to „--:--“ position. The setting “--:--” means unlimited heating time. In such case the heating will
not stop automatically and needs to be stopped manually.
Power relay board S2
Devices‘ fuses
F1 = T 2A H 250 V
Primary fuse protection for main electronics, light and fan.
F2 = T 315 mA L 250 V
Secondary protection for main electronics.
!
this setting may be carried out only by a skilled person. By all works on an open con-
trol unit disconnect the power supply on all phases. Do not change the jumper position
without disconnecting the power.
Risk of electric shock! Risk of damages to the unit!
Jumper JP5 for heating time limitation
X2
F2
F1
JP5
L N S1 WB FR N ST1 N
N L
L N
ST2
ST2
Mounting screws
Control board
F1
F2
6 h
12 h
unlimited
6
R
1224
6
R
1224
6
R
1224
Limitation up to 6 hours hea-
ting time (factory default)
Limitation up to 12 hours hea-
ting time
Unlimited heating time - no
automatic switch off if the „Au-
to-Stop“ parameter has been
set to „--:--“.