X2
F1
F2
Extension of the heating time limitation
By switching a jumper you can extend the time setting for sauna time from 6:00 to 12:00 hours or
to unlimited operation time. Please notice that such extension is only permitted for certain com-
mercial sauna cabins and may be restricted by the local legal regulations.
Open the control unit. The jumper is located in the middle of the top edge of the mainboard. Set
jumper to the required position. Close the control unit. Restore the power supply.
Jumper for heating time limitation ( 6 hrs default)
X2
F1
F2
X1
Jumper
rear side of the board
Device fuses
On the rear sinde of board you will find the protective fuses. For replacement make sure to use the
fuses of the same type and of the same resistance value.
F1 = T 2A
Fuse primary electronics as well as light and fan
F2 = T 250 mA
Fuse secondary electronics
Jumper
6:00 hours heating time limitation (factory default)
Jumper
12:00 hours heating time limitation
Jumper
no heating time limitation
Such work must be carried out exclusively by an expert. Prior to any kind of work
disconnect the control unit from the power supply on all phases. (Switch off main switch,
or trip the ground circuit breaker).
Risk of electric shock!
34
GB