13
GB
Electrical connections
The electrical connection may only be done
by a certified electrician in compliance with
the guidelines of the local utility company
and the VDE.
In general, there may be only one fixed connec-
tion to the network; therefore equipment should
be provided that makes it possible to disconnect
the system with all poles from the network with
a contact opening width of minimum 3 mm.
All electrical installations and all connection
lines that are installed inside the cabin must
be suitable for an ambient temperature of at
least 170 °C.
The power supply line is run to the load control
unit and connected to the power input terminals.
Install the sauna heater and the vaporizer in front
of the air intake according to the manufacturer’s
installation instructions.
Run the silicone line through the ductwork to
the power unit and connect it to the appropri-
ate terminals as directed in the wiring diagram.
Note:
In case there is no ductwork available drill
a hole next to the air intake opening and run the
heater line through this hole to the outside and
to the appropriate terminals in the control unit.
The silicone line must be buried to protect it
from outside influences. Therefore, use a suitable
cable-duct or a PVC-pipe through which you can
run the line up to the power unit.
Connecting
the
sauna
heater
The sauna lamp must be weatherproof protected
(IPx4) and resistant to the ambient temperature.
The sauna lamp may be installed at any location
but never in the vicinity of the rising hot air of
the heater.
Connecting the sauna lamp
To connect the vaporizer, use silicone connect-
ing lines 4 x 1,5 mm² as well.
Connecting the vaporizer
The control unit can detect water deficit if there
is a zero-potential feed at the WM-input.
Connecting a fan
The fan must be weatherproof protected (IPx4)
and resistant to the ambient temperature.
The fan can be mounted at any point, but never
near to rising hot air from the heater and as far
as possible from the installation position of the
IR lamp (may not be in the direct beam).
LSG
Connecting a power ex-
tension unit (LSG)
For details refer to the installation instructions
of the specific LSG unit.
Warning
: When connecting the va-
porizer make sure it is correctly attached to
the water bath (WB) and low water shutoff
(WM). If you switch these connections, you
disable the water deficiency function and
bypass the thermostat. As a result, the
vaporizer will overheat.
Risk of fire!