28
GB
Auto-Stop.
Switching off the sauna in humid
mode
In order to get the sauna cabin dry after humid
operation, the „after-heating“ mode will switch
on after your switch off the heater. The sauna
will be heated for approx. 30 minutes at 90°C
temperature. In the upper part of the display a
blinking symbol
will be shown. Additional-
ly the optional fan (if installed) will be switched
on to accelerate the ventilation.
The sauna unit automatically turns off once this
time has expired.
If you wish to interrupt the reheating phase be-
forehand, push the
-button again.
12:00
90°C
0 : 29
- - : - -
Temperature
Humidity
Auto-stop
Start time
Auto-Stop.
12:00
30°C
5 : 59
- - : - -
Temperature
Humidity
Auto-stop
Start time
12:15
30°C
5 : 59
- - : - -
Temperature
Humidity
Auto-stop
Start time
The vaporizer will be only activated when
some value is entered and shown under
„humdity“ paramater on the display (to disable
humid mode set the value to „--“).
Please pay attention that the vaporizer will
only switch on if the temperature in the sauna
cabin does not exceed the maximum limit for
the given humidity setting. If the sauna has
been used in dry (Finnish) mode the tempera-
ture should sink first under such limit.
For instance if you used the sauna with 90°C
und then switched to the humid mode, then
the vaporizer will only switch on after the tem-
perature will sink under the limit value.
The humdity intensity shown on the display
by connected humidity sensor corresponds to
the relative humidity of the air in % around the
humdity sensor. It is possible to pre-set and mo-
nitor the desired relative humdity in the sauna.
The allowed settings (temperature / humdity)
are shown on the below chart:
10
100
90
80
70
60
50
40
30
20
0
100
90
80
70
60
50
40
30
20
10
T
[° C]
rH
[%]