Product data sheet conform Ecodesign (EU), nr. 1254/2014 (Annex IV)
Supplier:
EnviroVent
Model:
energiSava 300
Climate zone
Type of control
SEC-Value
in kWh/m²/a
Energy class (SEC)
The annual electricity
consumption (AEC)
in kWh
The annual heating
saved (AHS)
in kWh
Average
Manual
-37,52
A
308
4403
Clock
-38,38
A
294
4425
1 Sensor (RH/CO2/VOC)
-40,01
A
269
4469
2 or more Sensors (RH/CO
2
/VOC)
-42,88
A+
216
4557
Cold
Manual
-80,12
A+
845
6720
Clock
-81,19
A+
832
6754
1 Sensor (RH/CO2/VOC)
-83,25
A+
806
6821
2 or more Sensors (RH/CO2/VOC)
-86,97
A+
753
6955
Warm
Manual
-13,12
F
263
2317
Clock
-13,86
E
250
2329
1 Sensor (RH/CO2/VOC)
-15,24
E
224
2352
2 or more Sensors (RH/CO2/VOC)
-17,62
E
171
2398
Type of ventilation unit:
Ventilation unit with heat recovery
Fan:
Variable speed EC fan
Type of heat exchanger:
Recuperative plastic cross-counterflow heat exchanger
Thermal efficiency:
86%
Maximum flow rate:
300 m³/h
Electric power input:
92 W
Sound power level Lwa:
44 dB(A)
Reference flow rate :
210 m³/h
Reference pressure difference:
50Pa
Specific Power Input (SEL):
0,21 W/m³/h
Control factor:
1,0 in combination with manual switch
0,95 in combination with clock
0,85 in combination with 1 sensor
0,65 in combination with 2 or more sensors
Leakage*:
Internal
0,8%
External
2,1%
Filter warning:
On the display of the ventilation unit / Manual switch / clock control.
Attention! For optimal energy efficiency and a proper operation a regular filter
inspection, cleaning or replacement is necessary.
Internet address for Assembly instructions:
www.envirovent.com
Bypass:
Yes; 100% Bypass
*Measurements executed by TNO according to the EN 13141-7 standard (TNO-report TNO 2013 M10230, February 2013)
12
ErP