background image

 

Z-VENT 

 

MODEL SVE SERIES  III 

INSTALLATION AND MAINTENANCE 

INSTRUCTIONS 

3” & 4”  

SPECIAL STAINLESS STEEL VENTING SYSTEM 

FOR GAS BURNING APPLIANCES  

CATEGORY I, II, III, & IV 

 

TESTED AND LISTED BY 

UNDERWRITERS LABORATORIES INC. 

 UL 1738 & ULC – S636-95  

 Note the following before installation of Z-Vent 

 

 ٭Examine all shipping components for possible shipping damage prior to installation. ٭ 

 

 ٭

The 

Z-Vent

 system must be free to expand and contract. Pipe must be properly supported. 

٭

 

٭

 

Proper joint assembly is essential for a safe installation. Follow these instructions exactly as written. 

Check severeness of joints upon completion of assembly.

  ٭

   

  

 ٭

Check for unrestricted vent movement through walls, ceilings and roof penetrations. 

٭

 

  

 ٭

Different manufacturers have different joint systems and adhesives.  Do Not Mix Pipe, Fittings or 

Joining methods from different manufacturers beyond the flue collar adaptor. 

٭

 

 

 

FLEXMASTER CANADA LTD 

452 ATTWELL DR. 

M9W 5C3  

ETOBICOKE, ONTARIO 

(416) 679-0045 

 

Z-FLEX US, INC. 

20 COMMERCE PARK, NORTH 

BEDFORD, N.H. 

 03110-691 

1(800) 654-5600 

 

Содержание Z-Vent SVE III Series

Страница 1: ...and contract Pipe must be properly supported Proper joint assembly is essential for a safe installation Follow these instructions exactly as written Check severeness of joints upon completion of assem...

Страница 2: ...e more than 3 ft 91 m from any other building opening gas utility meter service regulator or the like 6 Exterior mounted venting systems should be enclosed below the roof line with a chase to limit co...

Страница 3: ...rds termination NOTE Some flue collars may require the use of high temperature silicone sealant to make a positive pressure gas tight seal IMAGES 1 2 3 CLEARANCE TO COMBUSTIBLES SIDE WALL VENTING INST...

Страница 4: ...I III or IV appliances or downwards for Category III or IV appliances not less than 1 4 6 4 mm every 12 inches 305 mm to prevent collection of condensate at any location in the assembly Fasteners must...

Страница 5: ...5 IMAGE 8 IMAGE 9 ILLUSTRATION 2...

Страница 6: ...installed Where the vent passes through the roof a flashing must be used to maintain the required clearances and to protect from the elements The framed opening must be large enough to provide the nec...

Страница 7: ...be used to support the system 1 Install the Guy Band below the Rain Cap using the 10 24 screw and nut provided 2 Attach stainless steel or galvanized cable with a minimum rated capacity of 500lbs to e...

Страница 8: ...last pipe length and attach top support to pipe Leave 6 150 mm of pipe protruding from flashing so that rain cap may be installed and to allow for any adjustment to line up base tee properly see image...

Страница 9: ...s are completed be sure to go over the entire system to make sure all joints are secure and sealed correctly The seams and joints must be checked for tightness prior to using the venting system A qual...

Страница 10: ...XPRESS WARRANTY HAS BEEN MADE OR WILL BE MADE ON BEHALF OF SELLER WITH RESPECT TO THE Z VENT OR THE INSTALLATION OR REPLACEMENT OF THE Z VENT SELLER SHALL NOT BE LIABLE FOR ANY SPECIAL INCIDENTAL INDI...

Отзывы: