SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
07
02
Technical Specifications
energiSava 400
Supply voltage (V/Hz)
230/50
Protection degree
IP30
Dimensions (w x h x d) (mm)
677 x 765 x 564
Duct diameter (mm)
Ø180
External diameter condensate
discharge (mm)
Ø32
Weight (kg)
38
Filter class
G3 (F7 optional for supply)
Fan setting (factory setting)
1
2
3
Ventilation capacity (m
3
/h)
50
100
200
300
Permissible resistance ducts
system (Pa)
3 - 6
6 - 20
25 - 79
56 - 178
Rated power (excl. preheater) (W)
8.6
9.5 - 15.0
29.0 - 40.0
72.0 - 98.0
Rated current (excl. preheater) (AA)
0.10
0.12 - 0.14
0.24 - 0.31
0.51 - 0.70
Max. rated current (with preheater
switched on) (A)
6
Cos φ
0.38
0.45 - 0.40
0.56 - 0.58
0.60 - 0.61
Sound Power energiSava 400
Ventilation capacity (m
3
/h)
100
200
225
300
400
Sound
power
level
Lw (A)
Static pressure (Pa)
9
40 38 80 47 100 84 175 240 150 225
Housing emission dB(A) 29.5 32.5 40.5 40.5 43.5 47.5 51.0 53.0 54.0 54.5 57.0
Duct from dwelling dB(A) 31.5 34.5 46.5 48.0 48.5 50.0 56.5 57.0 58.0 59.0 60.0
Duct to dwelling dB(A) 42.5 47.5 57.0 59.0 60.5 62.5 66.0 68.5 69.5 70.5 71.5
In practice, the value may deviate 1 dB(A) as a result of measuring tolerances