Initial Installation

QUALIFIED INSTALLERS ONLY

Page 27

Table 6: Vent Part Numbers 

(must state if galvanized or black wanted)

M&G Duravent

Direct Vent Pro

ICC 

EXCELDirect 

Selkirk 

DIRECT-TEMP

 Amerivent 

AMV DV

Metal-Fab 

Sure-Seal DV*

Description

46DVA-06

4DL6

4DT-06

4D6

6” pipe length

4D7

7” pipe length

46DVA-09

4DL9

4DT-09

9” pipe length

46DVA-12

4DL1

4DT-12

4D12

4D12

12” pipe length

46DVA-18

4DT-18

4D18

18” pipe length

46DVA-24

4DL2

4DT-24

4D2

4D24

24” pipe length

46DVA-36

4DL3

4DT-36

4D3

4D36

36” pipe length

46DVA-48

4DL4

4DT-48

4D4

4D48

48” pipe length

46DVA-60

60” pipe length

46DVA-E30

30° elbow

46DVA-E45

4DE45

4DT-EL45

4D45L

4D45L

45° elbow

46DVA-E90

4DE90

4DT-EL90

4D90L

4D90A, 4D90L

90° elbow

46DVA-VSS, DVA-BVS

VSS

4DT-VS/VSK

4DHVS, DVSK

4DVS

Vinyl siding standoff/sheild

46DVA-WT, 46DVA-WTU

4WT

4DT-WT

4DWT

4DWT, 4DWT11 Wall thimble

46DVA-SC

SQSC, SC

4DT-SC

4DSC

4DSC

Storm collar

46DVA-WFS

4DT-FS

4DFSH

Wall Fire stop

46DVA-FS

4CS

4DT-FS

4DFSP

4DFS, 4DSPFS

Ceiling Fire stop

46DVA-IS

4AS

4DT-AIS

4DAIS12, AIS36

4DIS

Attic Insulation Shield

46DVA-WS

4WS

4DT-WS/B

4DWS

4DWS

Wall strap/support/band

46DVA-VCH

4SVT

4DVT

High wind vertical termination

46DVA-HC

4HT

4DT-HC

4DHCS

4DHT

High wind horizontal termination

46DVA-WG

4HTS

4DHWS

8DVTS

Horizontal Wind / Heat Guard

46DVA-VWG

4SVTS

Vertical Wind Guard

5DAL

3” to 10”  pipe, adjustable

 

46DVA-17TA

11” to 17” pipe, adjustable

46DVA-24TA

17” to 24” pipe, adjustable

4DLA30

16.5” to 29” pipe , adjustable

4DLS1

1 7/8” to 9” slip length pipe

4DLS2

1 7/8” to 21” slip length pipe

46DVA-F6

6EFA

4DT-AF6

4DF

5DF

Flashing, 0/12 to 6/12 roof pitch

46DVA-F12

6EFB

4DT-AF12

4DF12

5DF-12

Flashing, 7/12 to 12/12 roof pitch

46DVA-FF

6EF

5DFT

Flat Roof Flashings

46DVA-CFK

4MF

Masonary Flashing

46DVA-KCA

4CA6

4DT-CCKA

4DRCKA

Chimney Conversion Kit A 

[USA only]

46DVA-KCB

4CA7

4DT-CCKB

Chimney Conversion Kit B 

[USA only]

46DVA-KCC

4CA8

Chimney Conversion Kit C 

[USA only]

*

When using Metal-Fab Sure Seal a Duravent Appliance Adaptor, part #4DDA, is required

Содержание Q2GI

Страница 1: ...ion and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html C 4001609 W A R R A N T Y R E G I S T R A T I O N e n v i r o c o...

Страница 2: ...ur gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified...

Страница 3: ...t be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 5...

Страница 4: ...lass Door Removal 16 Burner Removal 16 Access Door 16 Fuel Conversion 17 Conversion Kit Installation 18 Initial Installation 20 Introduction 20 Placement and Framing 20 Framing Plate Installation 21 M...

Страница 5: ...SI Z21 88 CSA 2 33 VENTED GAS FIREPLACE HEATERS CAN CGA 2 17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES This ENVIRO Q2GI Q2GID Fireplace Has been certified for use with either natural gas or propane see...

Страница 6: ...never to be tampered with or removed All important information for your fireplace is on this label as well of the model specific serial number which you will need for warranty information Rating Labe...

Страница 7: ...any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPE...

Страница 8: ...ilot flame is burning normally and none of the burner ports are plugged Let the fireplace burn for roughly fifteen minutes and make adjustments as necessary The ideal flame will be blue at the base an...

Страница 9: ...PLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES IN THE BATTERY HOLDER Blue LCD display UP DOWN Arrow Key ON OFF Key THERMOSTAT Key MODE Key Remote Control Operations Proflame 2 is a modular rem...

Страница 10: ...radio frequency from the Transmitter to operate the appliance in accordance with the particular Proflame 2 system configuration The IFC has a red reset button at the front right corner that is used is...

Страница 11: ...see Figure 8 Turn on the Appliance Press the ON OFF Key on the Transmitter The Transmitter display will show all active Icons on the screen A single beep from the Receiver will confirm reception of t...

Страница 12: ...and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Key Figure 5 until...

Страница 13: ...he First Time Figure 15 Remote Control Locked Figure 16 Low Battery Indicator WARNING Fire Hazard Can cause severe injury or death The Receiver causes ignition of the appliance The appliance can turn...

Страница 14: ...a soft cloth Abrasive cleaners will damage the glass and painted surfaces Depending on the amount of use the glass should require cleaning no more than two or three times a season Do not clean the gla...

Страница 15: ...oval The door will occasionally need to be removed for installation of media and cleaning of the Glass Step 1 First remove the safety screen by grabbing the top and bottom of the frame and lifting it...

Страница 16: ...ure 21 Removing Access Door Access Door Step 1 Remove the burner as shown in the Maintenance and Service Burner Removal Step 2 Remove the Upper Air Diverter by removing 2 T 20 bolts Remove the Lower A...

Страница 17: ...APPLIANCE WAS CONVERTED ON _______DD MM YYYY TO LPG PROPANE WITH KIT NO 50 3061 BY _______________________________________ NAME AND ADDRESS OF ORGANIZATION MAKING THIS CONVERSION WHICH ACCEPTS REPONSI...

Страница 18: ...AN OPEN FLAME WHEN TESTING FOR LEAKS 12 Relight the pilot and confirm the flame properly covers the flame sensor see Figure 23 Should the pilot require adjustment turn the adjustment screw figure 36...

Страница 19: ...tion guidelines which state the sea level rated input of Gas Designed Appliances installed at elevations above 2000 610 m feet is to be reduced 4 for each 1000 feet 305 m above sea level Refer also to...

Страница 20: ...mm Minimum Framing Dimensions Depth 15 7 8 403mm Width 34 9 16 878mm Header Height 40 1016mm Chase Height Rear Vent N A N A Chase Height Top Vent 54 1372mm Gas Inlet Front 6 152mm Gas Inlet Height 1 1...

Страница 21: ...tible material is only necessary over the fireplace opening and does not need to span the entire width of the framing plate A wood mantle can we placed over top of the non combustible as long as it st...

Страница 22: ...opening and does not need to span the entire width of the framing plate In Front of Unit The Q2GI Q2GID can be placed on the floor if desired although it is recommended that it be raised aleast an in...

Страница 23: ...tle 49 48 47 46 45 44 43 42 1 2 3 4 5 6 7 8 9 10 11 12 M A N T L E H E I G H T M A N T L E D E P T H Minimum Mantle Clearances 12 MANTLE 2 MANTLE Figure 27 Mantle Clearances Note Mantle height dimensi...

Страница 24: ...vent and must be either correctly interlocked or fastened with three screws directly to the vent collar Check periodically that the vents are unrestricted Also ensure that all direct vent pipes have b...

Страница 25: ...be opened C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance...

Страница 26: ...t Because the length of the vertical and horizontal sections dramatically affects the burning efficiency of the fireplace certain guidelines have been set in Initial Installation Allowable Co Axial Ve...

Страница 27: ...VA WFS 4DT FS 4DFSH Wall Fire stop 46DVA FS 4CS 4DT FS 4DFSP 4DFS 4DSPFS Ceiling Fire stop 46DVA IS 4AS 4DT AIS 4DAIS12 AIS36 4DIS Attic Insulation Shield 46DVA WS 4WS 4DT WS B 4DWS 4DWS Wall strap su...

Страница 28: ...vent pipe can not exceed 20 feet 6 1m and the total vent length can not exceed 40ft 12 2m Any combination of rise and run can be used as long as it lays within the shaded area a total of three 3 90 e...

Страница 29: ...ION NOTES Do not bend flex vent over 90 degrees All horizontal runs should have a minimum 1 4 6mm rise per foot for optimal performance Do not allow the inner flex pipe to contact the outer pipe keep...

Страница 30: ...ween the wall and the vent termination The air gap prevents excessive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 914 mm Plumber s all round strap will suf...

Страница 31: ...the vent cap assembly to the outer wall of the vent pipe Bend any remaining portion of the strap back towards the vent cap Security Secure Vent uses a twist lock cap Step 5 Position the horizontal ven...

Страница 32: ...the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that you have at...

Страница 33: ...be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Figure 35 Sangle de mur Bande de plombier connect sangle du mur Coudes 45 x2 4 Any occupied areas above the first fl...

Страница 34: ...l manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water solution after...

Страница 35: ...hould be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug CAUTION When servicing controls label all wires prior to disconnection Wir...

Страница 36: ...ll sit over these holes It is perfectly acceptable should a few pieces fall through upon installation NOTE Make sure the pilot flame is un obstructed and has a clear path the burner Keep the pilot are...

Страница 37: ...indicator will blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Ad...

Страница 38: ...the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot for full flame imp...

Страница 39: ...ll Mount 50 3028 11 Enviro Gel Decal 50 322 12 Control Cover w Decal 50 3022 13 Battery Holder 4 x AA 50 3027 14 Proflame 2 Integrated Fireplace Control IFC 50 3791 Proflame 2 IFC Wire Harness 0 584 9...

Страница 40: ...9 7 10 12 13 16 3 11 14 6 4 1 5 8 15 2 17 17 18 20 19 Parts Diagram Page 40...

Страница 41: ...Notes Page 41...

Страница 42: ...Notes Page 42...

Страница 43: ...reen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over...

Страница 44: ...___________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy NA...

Отзывы: