Trouble Shooting
D
iagnostic
f
Lash
c
oDes
(
Does
not
appLy
to
q2giD
moDeLs
):
1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3
times in intervals until the system is reset.
2. Low battery condition (<4V): the LED indicator will blink one (1) time in intervals.
3. Parasitic Pilot Flame: the LED indicator will blink two (2) times in intervals.
4. System Lock out: the LED indicator will blink three (3) times in intervals.
Additional Ignition Information
1. The Proflame2 IFC will try two (2) times for ignition.
2. Each try for ignition will last approximately 60 seconds.
3. The wait time between the two tries is approximately 35 seconds.
Figure 40: IFC LED Location
LED Location
Page 37