Page 16
Maintenance And Service
b
uRneR
R
emovaL
:
The burner may need to be removed for a few reasons, including cleaning under the burner or fuel
conversion.
Proceed only when the unit has completely cooled down.
Figure 20. Removing Glass Tray
Step 1:
Remove the glass door as shown in
the
m
aIntenance
anD
s
erVIce
- g
lass
D
oor
r
emoVal
.
Step 3:
Unscrew the burner pan using a T20
screwdriver then rotate it clockwise and pull
it out of the venturi box (Figure 19).
To re-install the burner follow steps 1-3 in
reverse. When placing the burner back in
the unit be sure not to move the air shutter.
DATE: 8/6/2014
BY
SHERWOOD INDUSTRIES LTD.
INTERNAL ASSEMBLY MANUAL
THIS DRAWING IS THE PROPERTY OF SHERWOOD INDUSTRIES LTD. AND MAY NOT BE COPIED, REPRODUCED, OR OTHERWISE DISCLOSED WITHOUT THE PRIOR APPROVAL OF SHERWOOD INDUSTRIES LTD.
1 of 1
SHEET:
STOVE:
UPDATED: ----/--/--
BY --
REVISION:
0.0
Figure 21. Removing Access Door
a
ccess
D
ooR
:
Step 1
: Remove the burner as shown in
the
m
aIntenance
anD
s
erVIce
- B
urner
r
emoVal
.
Step 2:
Remove the Upper Air Diverter
by removing (2) T-20 bolts. Remove
the Lower Air Diverter.
Step 3
: Remove the right and left
burner stands by removing (4) T-20
bolts.
Step 4
: Remove the (16) T-20 bolts
retaining the access door as shown in
Figure 21.
Step 5
: After servicing assemble in the
reverse order and be sure the gasket
is still intact. Replace if necessary.
There is an access door in the bottom on the firebox that is used for servicing components after the unit
is installed in a construction enclosure.
Proceed only when the unit has completely cooled down.
Step 2:
Remove the glass media and the enameled glass
tray as shown in Figure 20
.
Figure 19. Removing Burner
Содержание Q2GI
Страница 40: ...9 7 10 12 13 16 3 11 14 6 4 1 5 8 15 2 17 17 18 20 19 Parts Diagram Page 40...
Страница 41: ...Notes Page 41...
Страница 42: ...Notes Page 42...