![Enterasys X-Pedition XSR Скачать руководство пользователя страница 468](http://html1.mh-extra.com/html/enterasys/x-pedition-xsr/x-pedition-xsr_cli-reference-manual_2414758468.webp)
ISDN Commands
11-90 ISDN BRI and PRI Commands
Example
The
following
example
selects
a
switch
type
on
the
BRI
1/1
interface:
XSR(config)#interface bri 1/1
XSR(config-if<BRI-1/1>)#isdn switch-type basic-net3
leased-line bri
This
command
sets
up
an
ISDN
BRI
port
for
leased
‐
line
operation.
Leased
‐
line
service
at
64
or
128
kbps
via
BRI
is
provided
in
Japan
and
Germany.
The
56
and
112
kbps
speeds
are
provided
for
eventual
North
American
deployment
of
this
service.
Once
a
BRI
interface
is
configured
for
access
over
leased
lines,
it
is
no
longer
a
dialer
interface,
and
signaling
over
the
D
‐
channel
no
longer
applies.
Although
the
interface
is
called
interface
BRI,
it
is
configured
as
a
synchronous
serial
port
and
all
serial
port
commands
are
available.
This
command
creates
a
serial
interface
that
is
configured
as
a
standard
serial
port.
It
can
be
issued
once
for
speeds
equal
to
and
higher
then
112
as
both
B
‐
channels
are
bound
to
the
created
serial
interface.
For
56
and
64
bps
speeds,
the
command
can
be
issued
twice
to
create
individual
serial
interfaces
:1
and
:2
for
B1
and
B2,
respectively.
After
you
enter
the
command,
you
must
exit
BRI
configuration
mode
and
configure
the
channels
by
entering
interface bri [board/port:1]
or
interface bri [board/port:2]
.
These
Bearer
ports
are
configured
as
regular
synchronous
serial
interfaces.
Syntax
leased-line bri
speed
{56 | 64 | 112 | 128 | 144}
Syntax of the “no” Form
The
no
form
of
this
command
cancels
leased
‐
line
BRI
by
deleting
the
earlier
created
serial
interface
and
returning
to
the
basic
‐
net3
ISDN
switch
‐
type:
no leased-line bri
Default
CMD/switch
type
basic
‐
net3
Mode
BRI
Interface
configuration:
XSR(config-if<xx>)#
Note:
The
shutdown
/
no shutdown
channel
commands are overridden by the
interface bri
shutdown
/
no shutdown
commands.
56 | 64
Two
streams
are
supported,
one
on
each
B
‐
channel.
112 | 128 |144
One
stream
is
supported
over
the
bonded
B1
+
B2
or
B1+
B2
+
D
‐
channels.
Содержание X-Pedition XSR
Страница 1: ...X Pedition Security Router XSR CLI Reference Guide Version 7 6 P N 9033842 07...
Страница 2: ......
Страница 10: ...viii...
Страница 14: ...xii...
Страница 134: ...Bootrom Monitor Mode Commands 3 128 Configuring the XSR Platform...
Страница 278: ...VRRP Clear and Show Commands 5 202 Configuring the Internet Protocol...
Страница 352: ...IGMP Clear and Show Commands 7 104 Configuring IP Multicast...
Страница 406: ...Multilink Show Commands 8 136 Configuring the Point to Point Protocol...
Страница 436: ...Frame Relay Clear and Show Commands 9 112 Configuring Frame Relay...
Страница 460: ...Dialer Watch Commands 10 106 Configuring the Dialer Interface...