![Enterasys X-Pedition XSR Скачать руководство пользователя страница 120](http://html1.mh-extra.com/html/enterasys/x-pedition-xsr/x-pedition-xsr_cli-reference-manual_2414758120.webp)
File System Commands
3-114 Configuring the XSR Platform
which
is
specified
in
the
flash:boot
‐
config
file.
Although
you
cannot
configure
the
secondary
EOS
file,
if
you
wish
to
rename
it,
use
the
boot system
command.
Be
aware
that
if
the
boot
‐
config
file
does
not
exist
in
the
flash:
directory,
EOS
fallback
will
seach
for
the
default
xsr1200.fls
,
xsr1800.fls
or
xsr3000.fls
file
first
in
flash:
,
then
in
cflash:
,
finally
over
the
network
(as
specified
in
the
bootrom
using
the
Bootrom
monitor
mode
commands
sn
or
np
).
When
you
reboot
the
router
using
reload
,
the
newly
loaded
startup-config
file
is
converted
to
the
running config
file.
The
command
initiates
a
script
requiring
confirmation
of
your
intention.
Be
aware
that
the
reload
command
does
not
appear
in
startup-config
.
For
more
information
on
how
to
use
this
command,
refer
to
the
Chapter
2:
Managing
the
XSR
in
the
XSR
User’s
Guide
.
Syntax
reload [in | at [
mmm
|
hh:mm
] | cancel | cold | warm | fallback] primary-file
{cflash: | flash:} duration [
config
| snmp [
ip-address
]]
Defaults
•
Warm
start
•
Primary
‐
OS
test:
10
minutes
Mode
Privileged
EXEC:
XSR#
in
Reloads
after
a
specified
interval,
expressed
in
minutes
or
hours:minutes.
at
Reloads
at
a
particular
time,
expressed
in
hours
and
minutes
.
cancel
Cancels
a
pending
reload.
primary-
file
The
filename,
including
the
device
name
(
flash:xsr1800.fls
,
for
example),
and
can
include
any
other
designation
of
up
to
31
ASCII
characters.
For
example:
flash:my_new_xsr1800.fls
or
cflash:8_12_04_xsr1800.fls.
cflash:
flash:
Reloads
primary
OS
file
from
cflash:
or
flash:
directory
and
tested
for
an
interval
you
specify
between
5
and
30
minues.
duration
Primary
OS
test
period
after
reload,
ranging
from
5
to
30
minutes.
config
Fallback
to
secondary
OS
file
if
any
syntax
error
is
found
in
startup
‐
config
.
snmp
Fallback
to
secondary
OS
file
if
no
SNMP
message
was
received
during
test.
ip-address
SNMP
manager
IP
address
to
be
monitored
for
received
messages.
If
no
SNMP
IP
address
is
specified,
any
received
SNMP
message
indicates
SNMP
communications
are
successful.
cold
XSR
hardware
is
re
‐
initialized
with
the
SDRAM
cleared
and
software
rebooted.
The
start
is
slower
since
hardware
diagnostics
are
performed.
warm
XSR
hardware
is
re
‐
initialized
and
software
rebooted.
The
start
is
faster
since
hardware
diagnostics
are
not
performed
during
the
reboot.
none
Lack
of
argument
performs
a
warm
start.
Содержание X-Pedition XSR
Страница 1: ...X Pedition Security Router XSR CLI Reference Guide Version 7 6 P N 9033842 07...
Страница 2: ......
Страница 10: ...viii...
Страница 14: ...xii...
Страница 134: ...Bootrom Monitor Mode Commands 3 128 Configuring the XSR Platform...
Страница 278: ...VRRP Clear and Show Commands 5 202 Configuring the Internet Protocol...
Страница 352: ...IGMP Clear and Show Commands 7 104 Configuring IP Multicast...
Страница 406: ...Multilink Show Commands 8 136 Configuring the Point to Point Protocol...
Страница 436: ...Frame Relay Clear and Show Commands 9 112 Configuring Frame Relay...
Страница 460: ...Dialer Watch Commands 10 106 Configuring the Dialer Interface...