Specifications
Entek IRD 6687 Protection Monitor
33
Power supply
Monitor
AC: 85–264 volts (50-400 Hz)
DC: +24 VDC (nominal), and must be b18 to +30 volts
Power consumption
Total module power is 15 VA
Peak load is 3.7A@24V for 250 ms following power up
Transducer
6691 unit supplies –24 VDC, +24 VDC, –18VDC, +18 VDC at
100 mA to power input transducers
Heat production
24 VDC power: 13-14 W typical, 15 W maximum
117 VAC power: 12-13 W typical, 14 W maximum
230 VAC power: 13-14 W typical, 16 W maximum
Physical attributes
Dimensions
15 inches long, 5.75 inches high, 2.44 inches wide
27.9 cm long, 14.6 cm high, 6.19 cm wide
Weight
1.45 kg (monitor, power supply, and backplane)
Environmental
Operating temperature
Normal operating range: –4° F to +131° F (–20° C to +55° C)
Storage temperature
Storage: –4° F to +167° F (–20° C to +75° C)
Relative humidity
0 to 95%, noncondensing
Conformal coated circuit board and components
Vibration
Vibration applied in three mutually-perpendicular planes,
10–58 Hz at constant displacement of 0.15mm,
58–500 Hz at constant acceleration of 1.0 g