UNCONTROLLED COPY WHEN DOWNLOADED OR PRINTED
Enstrom TH-28/480 Series Maintenance Manual Supplement 8
G1000H Integrated Flight Deck System
May
14/14
Page
3-3
SECTION 3
SERVICING, TROUBLESHOOTING, AND PERIODIC INSPECTIONS
3.3
Servicing, Troubleshooting, and Periodic Inspections
3.3.1
Servicing
The GDL 69AH contains no user serviceable components.
3.3.2
Troubleshooting
Refer to Section 4,
Troubleshooting,
in the G1000H Integrated Avionics System Standard
Maintenance Manual, 190-01739-00, and the electrical wiring diagrams in Section 5 of this
chapter.
3.3.3
Periodic Inspections
The following inspection checklist is intended as a guide for 100 hour/annual inspections
for aircraft operating under normal conditions. More frequent inspections may be required
should adverse operating conditions be encountered.
Date
Signature
Aircraft Registration Number
Aircraft Serial Number
GDL 69AH XM Weather Receiver
INITIAL EACH ITEM AFTER ACCOMPLISHMENT
Inspect the following items every 100 hours or annually
INITIAL
1. Inspect the GDL 69AH, GA 55 antenna, electrical cables, and
mounts for security, damage, and obvious defects.
2. Inspect the GDL 69AH and GA 55 antenna hardware for corrosion,
damage or obvious defects.
Visit www.enstromhelicopter.com for instructions to order an original manual and to register for email notification of updates.