Enstrom TH-28/480 Series Maintenance Manual Supplement 8
G1000H Integrated Flight Deck System
May
14/14
Page
1-23
1.4.5.6 ‘Set’ and ‘Active’ Commands
The SET and ACTIVE commands on various configuration pages are used for setting
input/output conditions (Figure 12. ‘Set’ and ‘Active’ Commands).
Figure 12. ‘Set’ and ‘Active’ Commands
When troubleshooting the system, the technician can look for inequalities (configuration
mismatches) between the SET and ACTIVE columns. Certain problems can be resolved
by pressing the SET>ACTV softkey which reloads settings to the specific LRU from the
PFD (this can also be accomplished by reloading the configuration files for the LRU using
the G1000H SW Loader Card).
Definitions:
SET
—refers to a setting or group of settings that reside in the PFDs internal memory
and/or master configuration module.
ACTIVE
—refers to a current setting stored and used in a LRU. LRUs store the ‘active’
settings within internal memory.
Data can be manually copied from one column to the other by using the following two
softkeys:
SET>ACTV
(Set to Active)—allows the installer to send the information in the SET
column (data stored in the master configuration module) to the ACTV column (data used
by the LRU).
ACTV>SET
(Active to Set)—causes the current settings of the LRU to be copied to the
master configuration module as SET items.