Configuration procedure
Page 8
Configuration Procedure
This chapter describes the general configuration procedure for the
880 CIU Prime, CIU Plus. For programming the 880 series CIU’s, it is
necessary to use
Ensite Pro.
It is programmable to communicate via one of the higher levels, i.e.
via a CIU Plus to a CIU Prime, or even via Entis Pro to any of the
connected CIU’s.
Procedure steps
The complete configuration procedure consists out of the
following steps:
•
Preparation
•
Retrieving configuration data of gauges.
•
Configuration of Tanks
•
Configuration of the CIU Prime(s)
•
Configuration of CIU Plus(‘s)
•
Linking Gauges, Tanks and CIU’s
Preparation
Before you start configuring 880 series CIU and possible one or
more Entis Pro stations, certain preparations are necessary.
Be sure that the following information is available:
•
Site layout
•
Field cabling information (which gauges are connected on the
same pair of field wires, etc.)
•
Tag names of field devices (gauges, CIU and tanks)
•
Tank information (strapping tables, or tank capacity tables, roof
details, etc.)
•
Information on the types of stored product
•
Host communication setup
(if applicable, i.e. modbus memory maps, etc.)
•
Modems and possible other communication hardware connected
to the CIU’s
The first step in Ensite Pro is the creation of a site.
This allows the program to store multiple configuration sets, with each
a separate database. After a new site has been created, the program
will prompt for a set of global settings. These settings are required for
initiating the configuration database.
Once the global settings are entered, Ensite Pro will create a site
database. If there is a .LOG file available for this gauge it can be
extracted by Ensite Pro. The data extraction pre-sets all the relevant
configuration parameters. The next step is the creation off all tanks.