ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader 

SECO-LARM U.S.A., Inc. 

5

 

Status 

Sounds 

LED 

Power on in standby mode 

-- 

Red steady 

In base programming mode 

1 Beep 

Red flashing 

In function programming mode 

1 Beep 

Orange steady 

Exit programming mode 

1 Beep 

Red steady 

Successful operation 

1 Beep 

Green flash once 

Unsuccessful operation 

3 Beeps 

 

Built-in alarm 

Rapid beeping* 

Red flashing rapidly 

 

LED Indicators and Device Sounds:  

*De-activate the built-in alarm by entering a valid user code. 

1.

 

Find a suitable location to mount the keypad. Install at a 
height convenient to most users. 

2.

 

Using the included security wrench, remove the security 
screw located on the bottom of the keypad (Fig. 1). 

3.

 

Carefully remove the keypad from the housing base, 
sliding the keypad slightly upwards.  

4.

 

Using the housing base as a template, mark the holes 
needed for the wiring and mounting screws and drill 
needed holes (choose either of the two pairs of mounting 
holes). Ensure that the wiring hole is large enough to 
allow the wiring to be pushed in without crimping. 

5.

 

Run wiring through the wall to the wiring hole in the wall  

6.

 

Thread the keypad wires through the center of the keypad 
base and connect all according to "Wiring Chart" on pg. 6.  

7.

 

Carefully push the wires through the hole in the wall. 

8.

 

Install the base using the included mounting screws and mounting screw anchors (if necessary). 
Ensure the correct orientation as shown in Fig. 1. 

9.

 

Finish assembly by reattaching the keypad to the base and securing with the security screw. 

 

Important Notes:  

1.

 

Always disconnect power before servicing the keypad. Do not apply power until all connection wiring 
is completed. 

2.

 

The keypad must be properly grounded. Use a minimum 22AWG wire connected to the common 
ground wire. Failure to do so may damage the unit. 

3.

 

All wiring and programming should be done by a professional installer to reduce the risk of improper 
installation. 

4.

 

Be sure to store this manual in a safe place for future reference. 

Installation: 

 

Fig. 1 

Drill 2 mounting 

holes 

Drill at least ø

3

/

8

(ø9mm) wiring hole 

NOTE:

 For weatherproof installation, add a 

bead of silicone sealant around the 

base where it meets the wall.  

Security 

screw 

IF USING THE KEYPAD WITH A MECHANICALLY OPERATED DOOR OR 

GATE, MOUNT THE UNIT AT LEAST 15' (5m) FROM THE DOOR OR GATE 

TO PREVENT USERS FROM BEING CRUSHED OR PINNED. FAILURE TO 

DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. 

Содержание SECO-LARM SLI SK-2612-SPQ

Страница 1: ...ernal alarm output Backlit keypad and multicolor status LED EM 125kHz Outdoor rated IP66 Easy transfer of users to additional devices EEPROM Memory protects programmed information in case of power los...

Страница 2: ...event operation of the strike from damaging the keypad Do not connect a diode when using electromagnetic locks or with AC powered strikes Quick Installation Guide Orange Output N C Blue Output N O Yel...

Страница 3: ...ions carefully before proceeding 1 Enter base programming mode NOTE is the factory default master programming code A new master programming code 6 digits should be set the first time you enter program...

Страница 4: ...Installation Guide 2 Mounting Diagram 2 Quick Wiring Diagram 2 Quick Programming Guide 3 Table of Contents 4 Specifications 4 Overview 4 Parts List 4 LED Indicators and Device Sounds 5 Important Note...

Страница 5: ...g hole in the wall 6 Thread the keypad wires through the center of the keypad base and connect all according to Wiring Chart on pg 6 7 Carefully push the wires through the hole in the wall 8 Install t...

Страница 6: ...to the first available user ID in consecutive order Master delete card Used only to quickly delete user cards without entering programming mode User cards Up to 998 user cards user IDs 0 997 can be a...

Страница 7: ...for that function It should not be repeated between each parameter Programming Format and Default Values Getting Ready to Program Continued Enter and Exit Base Programming Mode All programming of the...

Страница 8: ...keypad can be programmed to one of four access modes security levels Card only a user must use a card for access Either card or code a user may use either a card or a user code for access default Card...

Страница 9: ...er codes or cards in any order up to the set number must be used with no more than 5 seconds between each code or card No particular user code or card can be repeated This is used for extremely secure...

Страница 10: ...d Users function code a short beep will sound and the LED will change to steady orange to the beginning user ID the number of cards fobs to be added the card number 8 10 digits for the first card or r...

Страница 11: ...e Master Add Card again to return to standby mode NOTES It is important to record each User ID assigned in order to simplify future user management A user ID can only have a single card or single code...

Страница 12: ...function code For a Code User You can change the user code for an existing user without going into programming mode if you know both the current user code and user ID Users can also use this method to...

Страница 13: ...e a short beep will sound and the LED will change to steady orange Master programming code NOTES Duress IDs cannot be deleted using their user code or card but must be deleted with the Duress ID Any o...

Страница 14: ...se the following general formula from within base programming mode see Enter and Exit Base Programming Mode pg 7 Program Output Mode and Time function code a short beep will sound and the LED will cha...

Страница 15: ...tion sounds affects only the internal sounds and not the external alarm output The duress alarm and wrong code alarm will trigger both the internal notification beep and the external alarm depending o...

Страница 16: ...deny access for 10 minutes Enable wrong code alarm to sound the keypad notifications external alarm NOTES If wrong code lockout is enabled the LED will flash red and all access will be denied for 10...

Страница 17: ...Door 2 Door 1 Wiegand Controller Wiegand Controller 12VDC Power Supply Door 2 electric Lock 2 3 4 9 0 7 8 5 6 2 3 4 9 0 7 8 5 6 NOTE For DC powered electric strikes connect the included diode as clos...

Страница 18: ...itten When transfer is complete a short beep will sound the LED will flash green once and change to red Exit programming mode by pressing the key after transfer is complete Wiegand Controller Mode The...

Страница 19: ...Base Programming Mode pg 7 Set Wiegand Input Bits PIN Input Format function code a short beep will sound and the LED will change to steady orange Wiegand Input Bits PIN Input Format Wiegand Input Bit...

Страница 20: ...f any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglec...

Отзывы: