Programming the Wrong-Code Lockout/Alarm:
The device can be programmed to either lockout or sound an internal alarm after 10 successive wrong
cards/codes. The lockout continues and the LED flashes red for 10 minutes and cannot be reset before
then. The built-in notifications and external alarm sounds for the length of time set in the alarm settings
(1~3 minutes, see notes below), or until stopped with a valid master programming code or user code.
When programming the wrong code lockout, use the following general formula from within base
programming mode (see "Enter and Exit Base Programming Mode," pg. 7):
– Program Wrong-Code Lockout/Alarm function code (LED will change to steady orange)
–Disable or Enable/Configure the Wrong-Code Lockout/Alarm
Disable or Enable/Configure Wrong-Code Lockout/Alarm:
– Disable wrong-code lockout (factory default)
– Enable wrong-code lockout to deny access for 10 minutes
– Enable wrong-code alarm to sound the keypad notifications / external alarm
NOTES:
If wrong-code lockout is enabled, the LED will flash red and all access will be denied for 10 minutes
after 10 successive wrong cards/codes.
If wrong-code alarm is enabled, the LED will flash red and the built-in notifications (if enabled, see
"Programming the Notification Sounds, LED, and Backlight," pg. 15) and external alarm (if enabled,
see "Programming the External Alarm Output, pgs. 15~16) will sound and continue for the length of
time programmed for the alarm or until a valid master programming code or user code is entered.
This setting requires either or both the built-in notifications and external alarm output to be enabled
and the alarm timing is set by the external alarm settings.
The key returns you to base programming mode (the LED will flash red). Exit programming mode
by pressing the key (see "Enter and Exit Base Programming Mode," pg. 7).
Examples:
1.
Disable the wrong-code lockout:
2.
Enable the wrong-code lockout to deny access for 10 minutes:
3.