background image

ENFORCER Outdoor Stand-Alone/Wiegand Keypad with Proximity Reader 

20

 

SECO-LARM U.S.A., Inc. 

The keypad must be connected to a Request-to-Exit (RTE) button to be reset to factory default settings. 
When resetting to factory default, user information is retained. You may also program new Master Add 
and Master Delete Card if they are lost. To reset the keypad to factory default settings, follow steps 1~4 
below. To also program new Master Add and Master Delete cards, follow steps 1~3 and 5 below. 

NOTE: 

Programming new Master Add and Master Delete cards will delete the previous Master Add and 
Master Delete cards. 

1.

 

Power off the keypad 

2.

 

Hold down the egress button and power the keypad on, continuing to hold down the egress button 
for approximately 10 seconds until you hear 2 beeps and the LED turns orange. 

3.

 

Release the egress button. 

4.

 

If you only need to reset the keypad to factory default, wait until the LED changes to red (about 30 
seconds) indicating that the reset has completed successfully. 

5.

 

If you need to program new Master Add and Master Delete Cards, within 30 seconds, read two 
cards. The first will become the Master Add Card, and the second the Master Delete Card. The LED 
will change to red indicating that the reset has completed successfully. 

Resetting to Factory Default and Programming Add/Delete Cards: 

Additional Accessories Available from 

SECO-LARM

 

®

 

 

 

 

SECO-LARM

 

®  

U.S.A., Inc.

 

16842 Millikan Avenue, Irvine, CA 92606 

Website: www.seco-larm.com 

Phone: (949) 261-2999  |  (800) 662-0800  Email: [email protected] 
 

®

 

PICSN8 

 

MI_SK-2612-SPQ_191030.docx 

 

NOTICE: 

The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to 

change  specifications  without  notice.  SECO-LARM  is  also not  responsible  for misprints.  All  trademarks  are  the property  of SECO-LARM 
U.S.A., Inc. or their respective owners. Copyright © 2019 SECO-LARM U.S.A., Inc. All rights reserved. 

WARRANTY:

 This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) 

year from the date of sale to the original customer. SECO LARM’s obligation is limited to the repair or replacement of any defective part if the 
unit is returned, transportation prepaid, to SECO LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or 
electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO 
LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The 
sole obligation of SECO LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO LARM’s 
option. In no event shall SECO LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any 
kind to the purchaser or anyone else.  

 

IMPORTANT:

 

Users and installers of this product are responsible for ensuring that the installation and configuration of this product complies 

with all national, state, and local laws and codes related to locking and egress devices. SECO-LARM will not be held responsible for the use 
of this product in violation of any current laws or codes. 

FCC COMPLIANCE STATEMENT 

FCC ID:  K4E2612SPQ 

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 
(1) THIS  DEVICE  MAY  NOT  CAUSE  HARMFUL  INTERFERENCE  AND  (2) THIS  DEVICE  MUST  ACCEPT  ANY  INTERFERENCE 
RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 
Notice:  The changes or  modifications  not  expressly  approved  by  the  party responsible  for compliance could void  the  user’s  authority to 
operate the equipment. 
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. 
Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to 
operate the device.

 

IMPORTANT WARNING:

 

For a weather-resistant installation, ensure that the unit is properly sealed where the housing base meets the wall. 

Incorrect mounting may lead to exposure to rain or moisture in the enclosure which could cause a dangerous electric shock, damage the 
device, and void the warranty. Users and installers are responsible for ensuring that this product is properly installed and sealed. 

PR-K1K1-AQ 

Proximity key fobs 
(sold in packs of 10) 

 

PR-K1S1-A 

Proximity cards 
(sold in packs of 10) 

 

 

Содержание SECO-LARM SLI SK-2612-SPQ

Страница 1: ...ernal alarm output Backlit keypad and multicolor status LED EM 125kHz Outdoor rated IP66 Easy transfer of users to additional devices EEPROM Memory protects programmed information in case of power los...

Страница 2: ...event operation of the strike from damaging the keypad Do not connect a diode when using electromagnetic locks or with AC powered strikes Quick Installation Guide Orange Output N C Blue Output N O Yel...

Страница 3: ...ions carefully before proceeding 1 Enter base programming mode NOTE is the factory default master programming code A new master programming code 6 digits should be set the first time you enter program...

Страница 4: ...Installation Guide 2 Mounting Diagram 2 Quick Wiring Diagram 2 Quick Programming Guide 3 Table of Contents 4 Specifications 4 Overview 4 Parts List 4 LED Indicators and Device Sounds 5 Important Note...

Страница 5: ...g hole in the wall 6 Thread the keypad wires through the center of the keypad base and connect all according to Wiring Chart on pg 6 7 Carefully push the wires through the hole in the wall 8 Install t...

Страница 6: ...to the first available user ID in consecutive order Master delete card Used only to quickly delete user cards without entering programming mode User cards Up to 998 user cards user IDs 0 997 can be a...

Страница 7: ...for that function It should not be repeated between each parameter Programming Format and Default Values Getting Ready to Program Continued Enter and Exit Base Programming Mode All programming of the...

Страница 8: ...keypad can be programmed to one of four access modes security levels Card only a user must use a card for access Either card or code a user may use either a card or a user code for access default Card...

Страница 9: ...er codes or cards in any order up to the set number must be used with no more than 5 seconds between each code or card No particular user code or card can be repeated This is used for extremely secure...

Страница 10: ...d Users function code a short beep will sound and the LED will change to steady orange to the beginning user ID the number of cards fobs to be added the card number 8 10 digits for the first card or r...

Страница 11: ...e Master Add Card again to return to standby mode NOTES It is important to record each User ID assigned in order to simplify future user management A user ID can only have a single card or single code...

Страница 12: ...function code For a Code User You can change the user code for an existing user without going into programming mode if you know both the current user code and user ID Users can also use this method to...

Страница 13: ...e a short beep will sound and the LED will change to steady orange Master programming code NOTES Duress IDs cannot be deleted using their user code or card but must be deleted with the Duress ID Any o...

Страница 14: ...se the following general formula from within base programming mode see Enter and Exit Base Programming Mode pg 7 Program Output Mode and Time function code a short beep will sound and the LED will cha...

Страница 15: ...tion sounds affects only the internal sounds and not the external alarm output The duress alarm and wrong code alarm will trigger both the internal notification beep and the external alarm depending o...

Страница 16: ...deny access for 10 minutes Enable wrong code alarm to sound the keypad notifications external alarm NOTES If wrong code lockout is enabled the LED will flash red and all access will be denied for 10...

Страница 17: ...Door 2 Door 1 Wiegand Controller Wiegand Controller 12VDC Power Supply Door 2 electric Lock 2 3 4 9 0 7 8 5 6 2 3 4 9 0 7 8 5 6 NOTE For DC powered electric strikes connect the included diode as clos...

Страница 18: ...itten When transfer is complete a short beep will sound the LED will flash green once and change to red Exit programming mode by pressing the key after transfer is complete Wiegand Controller Mode The...

Страница 19: ...Base Programming Mode pg 7 Set Wiegand Input Bits PIN Input Format function code a short beep will sound and the LED will change to steady orange Wiegand Input Bits PIN Input Format Wiegand Input Bit...

Страница 20: ...f any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglec...

Отзывы: