background image

 

Eurostar Installation and Operation Manual 

59 

Item 

Description 

Qty 

35 SE44144 

EXHAUST 

FAN 

ASSEMBLY 

36  21382 

OUTLET EXHAUST BLOWER GASKET 

37  PL64462 

BLOWER OUTLET SPACER 

38 PL64463 

ROUND 

EXHAUST 

PLATE 

39  21392 

EXHAUST ADAPTER GASKET 

40  30762 

VENT ADAPTER SECURE CLAMP 

41 SE64345 

VENT 

ADAPTER 

42 SE64493 

HOPPER 

LID 

43 30029 

CUTTING THREAD SCREW 10-24 TYPE "F" X 3/8"  HEX 
WASHER 

10 

44  30013 

HINGE 2'' X 1-1/2'' 

45  30693 

HOPPER LID HANDLE 

46 30757 

RUBBER 

BUMPER 

47  24229 

CAST IRON TOP 

48 SE64394 

TOP 

GRILL 

49  24177 

CAST IRON UPPER GRILLE EUROZONE 35(DRILL & TAP) 

50  SE62334 

FRONT DECORATIVE PANEL 

51  AC06820 

EPDM GASKET KIT 4.5 FT 

52 99999 

BUILD 

TO 

ORDER 

53 99999 

BUILD 

TO 

ORDER 

54  44098 

HOPPER LID SAFETY SWITCH 

55  PL64490 

HOPPER LID SUPPORT 

56 SE62421 

LCD 

BRACKET 

57  SE64358 

LCD WITH  HOUSING 

58  PL64358 

EUROSTAR TOUCH SCREEN ELECTRONIC BOARD (LCD) 

59 30710 

SPRING 

CLIP 

60  SE64459 

PC BOARD WITH HOUSING 

61 30408 

ELECTRONIC 

BOARD 

CLIP 

62  PL64357 

MOTHER BOARD 6 OUPUT 

63  44015 

FUSE 5A / 250V / 1/4" DIA. X 1 1/4'' LONG 

64  44016 

FUSE 3A / 250V / 1/4" DIA. X 1 1/4'' LONG 

65  44013 

FUSE 7.5A / 250V / 1/4" DIA. X 1 1/4'' LONG 

66  60330 

MAIN BOARD WIRE HARNESS 

67  44106 

GEAR MOTOR FOR PELLET STOVE 1.7 RPM 

68  SE24233 

GEAR MORTOR SUPPORT ASSEMBLY 

69  21193 

AUGER SUPPORT GASKET 

70  30092 

BOLT 5/16''-18 X 3/4" HEX GRADE 5 

71  24017 

CAST IRON AUGER 

72  44059 

THERMODISC 36T11 L250-25 AUTOMATIC 

73 99999 

BUILD 

TO 

ORDER 

74 PL64337 

TOP 

REAR 

PANEL 

Содержание EUROSTAR

Страница 1: ...NSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH READ AND KEEP THIS MANUAL FOR REFERENCE PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED This manual is available for free download on the manufacturer s w...

Страница 2: ... you build and maintain your pellet heating system We highly recommend that our pellet burning hearth products be installed and serviced by professionals who are certified in the United States by NFI National Fireplace Institute or in Canada by WETT Wood Energy Technology Transfer or in Quebec by APC Association des Professionnels du Chauffage Congratulations on making a wise purchase REGISTER YOU...

Страница 3: ...ion 15 4 4 1 Permitted Termination Location 16 4 5 Installation Configurations 17 4 5 1 Installation Warnings Cautions and Recommendations Reminder 17 4 5 2 Through Wall Installation Main Floor or Basement 18 4 5 3 Through Roof Installation 19 4 5 4 Through a Prefabricated Chimney 20 4 5 5 Through an Existing Masonery Fireplace 21 4 5 6 Through an Existing Masonery Chimney 22 PART B OPERATION 23 5...

Страница 4: ...stem 41 8 1 6 Glass Care 41 8 1 7 Replacement of Broken Door Glass 41 8 1 8 Door Gasket Maintenance 42 8 1 9 Door Adjustment 42 8 1 10 Exhaust Channel and Exhaust Blower Maintenance 42 8 2 Venting System Maintenance 44 8 2 1 Dealing With a Chimney Fire 44 8 2 2 Soot and Fly Ash 44 9 Troubleshooting 45 9 1 Validating Status 45 9 2 Testing Components 46 9 3 Main Error Codes Possible Causes and Solut...

Страница 5: ...nly reduce dependence on finite supplies of fossil fuels like oil and gas but they also put to good use materials that would otherwise unnecessarily and expensively add to our waste disposal problems In addition pellet stoves burn very cleanly and offer the lowest emissions of unwanted pollutants of all solid fuel burning appliances 1 1 1 Top 10 Reasons for Buying a Pellet Stove Fuel is relatively...

Страница 6: ...ending on EVL see Section 4 3 Equivalent Vent Length EVL Baffle material Stainless Steel Burn rate 1 5 lb to 5 5 lb per hour Energy consumption 3A for ignition cycle 1 8A for maximum continuous operation Electrical requirements 120VAC 15A Control board fuses Main 7 5A 250V fast blow fuse Convection blower 5A 250V fast blow fuse Combustion blower 3A 250V fast blow fuse Exhaust blower 3A 250V fast b...

Страница 7: ...Eurostar Installation and Operation Manual 7 1 3 Overall Exterior Dimensions A FRESH AIR INTAKE B EXHAUST ...

Страница 8: ...OW CONCENTRATION THIS GAS IS EVACUATED BY THE VENTING SYSTEM IN HIGHER CONCENTRATIONS CARBON MONOXIDE IS TOXIC AND MAY CAUSE DEATH TO PREVENT THIS ENSURE THAT YOUR VENTING SYSTEM IS AIRTIGHT THIS STOVE IS MOBILE HOME APPROVED AND REQUIRES INSTALLATION OF A FRESH AIR KIT SOLD SEPARATELY THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME AND THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FL...

Страница 9: ...SOOT OR CREOSOTE NEVER BLOCK ANY LOUVERS OF THE STOVE IF REQUIRED A FRESH AIT KIT CAN BE INSTALLED TO SUPPLY COMBUSTION AIR TO THE ROOM OR SPACE see Appendix F Combustion Air Supply MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING COMPONENTS IS PROHIBITED AND WILL VOID THE WARRANTY ANY MODIFICATION OF THE STOVE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS PRO...

Страница 10: ...ystem complying with the requirements for Pellet Vent in the standards UL 103 ULC S629M ULC S609 and UL 641or to a code approved masonry chimney with a stainless steel flue liner 2 3 Before Operating Your Stove Some minor installation and adjustment are required prior to use If desired LCD sliding support can be installed on the left at the back of the stove see Appendix B LCD Sliding Bracket Moun...

Страница 11: ...MAKE ANY COMPROMISES WHEN INSTALLING THIS STOVE 3 1 Location of the Certification Label Since the information given on the certification label affixed to the stove always overrides the information published in any other media owner s manual catalogues flyers magazines and or web sites it is important to refer to it in order to have a safe and compliant installation In addition you will find import...

Страница 12: ...install the LCD sliding support on the left side of the stove see Appendix B LCD Sliding Bracket Mounting 3 4 Corner Installation For a corner installation in order to allow the LCD sliding support to move freely and fully extend you should allow a minimum of 6 160 mm clearance to the adjacent walls C However if you wish to install the stove with minimum clearances see table in Section 3 2 Minimum...

Страница 13: ...CONTINUOUS GROUTED JOINTS NONCOMBUSTIBLE MATERIAL SUCH AS CERAMIC TILE CEMENT BOARD BRICK MILLBOARD OR EQUIVALENT OR ANY OTHER APPROVED OR LISTED MATERIAL SUITED FOR FLOOR PROTECTION Any type of tile will require a continuous non combustible sheet beneath to prevent the possibility of embers falling through to the combustible floor if cracks or separation should occur in the finished surface this ...

Страница 14: ... Standard A pellet vent listed to ULC 103 is also suitable for installation with this stove This stove can be vented in an existing factory built or masonry chimney with the addition of a stainless steel liner provided the chimney is more than 4 in diameter The liner should be listed and should meet the ULC S 635 640 standard in Canada and the UL 1777 standard in the USA Refer to the instructions ...

Страница 15: ... 3 vertical length of 4 3 X 4 X 0 5 6 of EVL Total EVL 2 5 6 13 EVL is less than 15 therefore it is correct to use a 3 pipe NOTE Do not include the exterior wall termination in the EVL calculation 45 elbow and termination 4 4 Termination Location Termination should not be located so that hot exhaust gases can be a hazard They can reach temperatures of 500 ºF and cause serious burns CAUTION TERMINA...

Страница 16: ... window or door that may be opened F 39 100 cm Clearance to corner or adjacent wall H 39 100 cm Not to be installed above a meter regulator assembly within 39 100 cm horizontally from the vertical center line of the regulator and for 15 vertically I 72 183 cm Clearance to gas service regulator vent outlet or within 39 100 cm of an oil tank vent or an oil tank fill inlet J 39 100 cm Clearance to th...

Страница 17: ...y apply See NFPA 211 for further information 4 5 Installation Configurations 4 5 1 Installation Warnings Cautions and Recommendations Reminder PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED THIS STOVE USES A PRESSURIZED VENTING SYSTEM ALL VENT CONNECTOR JOINTS MUST BE SEALED AND FASTENED CONSULT THE PELLET VENT MANUFACTURER S INSTRUCTION TO ENSURE PROPER INSTALLATION CONSISTENT PERFORMANCE AND T...

Страница 18: ...ng length to go through the wall thimble and extend at least 6 inches beyond the exterior wall 4 Attach cap and seal outside wall thimbles with high temperature waterproof silicone sealant CAUTION TO REDUCE THE RISK OF SMOKE SPILLAGE THERE SHOULD ALWAYS BE AT LEAST ONE FOOT OF VERTICAL RISE FOR EACH FOOT OF HORIZONTAL RUN IN ALL CASES AT LEAST 3 FEET OF VERTICAL RISE IS NEEDED WARNING TERMINATION ...

Страница 19: ...d mark location on the ceiling Install the ceiling support and the vent pipe by following the vent manufacturer s instructions 4 Always follow vent manufacturer s clearances instructions from combustible materials When passing through additional floors or ceilings always install a fire stop spacer 5 After lining up for hole in roof cut either a round or square hole in roof Install upper edge and s...

Страница 20: ...tove exhaust If necessary use a horizontal additional length between the exhaust and the tee If you wish to center the vertical part of the vent with the stove a 45 elbow and a tee can be used to route the pipe from the exhaust towards the back center of the stove 3 Connect the pellet vent to the stainless steel liner according to the vent manufacturer s instructions 4 Seal and install vertical ro...

Страница 21: ...the exhaust making sure the clean out tee is centered in the chimney flue area 4 Build and install flashing above the fireplace Stainless steel plate and screws are recommended Cut a hole for the vent pipe If needed cut a second hole for the air intake pipe Seal all joints with high temperature waterproof silicone sealant to prevent water leakage 5 Seal and install vertical roof vent If required s...

Страница 22: ...the air intake pipe Seal all joints with high temperature waterproof silicone sealant to prevent water leakage 5 Install the cleanout tee at the bottom of the vertical vent system and lower it down the chimney until the center branch of the tee is aligned with the hole in the masonry 6 Install and seal flashing with high temperature waterproof silicone sealant 7 Seal and install vertical roof vent...

Страница 23: ...MAY CAUSE SKIN BURNS GLOVES MAY BE NEEDED FOR STOVE OPERATION THIS STOVE MUST SERVE AS A SUPPLEMENTARY HEAT SOURCE AN ALTERNATIVE HEAT SOURCE SHOULD BE AVAILABLE IN THE HOME IF NEEDED THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR ADDITIONAL HEATING COSTS ASSOCIATED WITH THE USE OF AN ALTERNATIVE HEAT SOURCE USING A STOVE WITH CRACKED OR BROKEN COMPONENTS SUCH AS GLASS OR BAFFLE MAY PRODUCE AN UN...

Страница 24: ...D CALL YOUR DEALER IF NECESSARY DO NOT UNPLUG IT NEVER OPEN THE DOOR IT IS RECOMMENDED TO UNPLUG THE STOVE WHEN IT S NOT IN USE FOR PROLONGED AMOUNT OF TIME I E DURING SUMMER SENSORS ON THE STOVE ARE ACTIVATED BY HEAT AND COULD ACTIVATE THE FANS EVEN IF THE STOVE IS NOT IN FUNCTION THIS STOVE REQUIRES REGULAR MAINTENANCE AND CLEANING FAILURE TO FOLLOW THE MAINTENANCE SCHEDULE SEE SECTION 8 1 1 REC...

Страница 25: ...DS JUST BEFORE THE IGNITOR IS HOT ENOUGH TO FIRE UP THE PELLETS IN THE BURN POT THIS IS NORMAL AS SOON AS THERE IS FIRE IN THE BURN POT SMOKE WILL DISAPPEAR MAINTAIN PROPER VENTILATION IT IS IMPORTANT THAT ADEQUATE OXYGEN IS BEING SUPPLIED TO THE FIRE FOR PROPER COMBUSTION DURING THE WINTER SEASON MAKE SURE THAT THE FRESH AIR INTAKE IS FREE OF ANY ICE AS THIS WILL STARVE THE FIRE OF AIR AND PREVEN...

Страница 26: ...n straight wood pellets Ignition may be more difficult than straight wood pellets Bark pellets 100 bark pellets Produce a hard crust that will be pushed into the ash drawer Their ash content is very high Ignition may be more difficult than straight wood pellets Switch grass pellets 100 switch grass Vary from medium to high content depending on when switch grass is harvested A light and friable cru...

Страница 27: ... the stove when facing it See Appendix B LCD Sliding Bracket Mounting for left hand side installation 6 1 1 LCD Touch Screen Controls Operation and Configuration The LCD control is an electronic visual display as well as a touch screen that will light up as you touch any location on the display area The Main Status Page will then display different icons layout depending if manual or thermostat mod...

Страница 28: ...hermostat mode Indicates that the stove is in thermostat mode in pilot cycle waiting for heat calling Indicates that the stove is in thermostat mode but not calling for heat and pilot cycle is completed Selecting the letter icon will display a menu screen where you can access the following pages Set up Trouble shoot Statistics and Program see Section 6 1 2 Configuration and Operation Diagram Selec...

Страница 29: ...lay temperatures in the desired unit MENU HEAT LEVEL PILOT MODE STATUS PAGE SETUP TROUBLE SHOOT STATISTICS PROGRAM LANGUAGE º F º C MODE LCD VERSION _ __ I O VERSION _ __ RUN TIME 0 00 00 IGNITOR RUN TIME 0 00 00 THERMISTOR PEAK ___ºF PAGE 1 MENU Return to status page This page is locked with a security code It will help technical service troubleshoot the unit if needed This page will help the use...

Страница 30: ... may need to adjust the PILOT SETTING ADJUSTMENT and the FUEL QUALITY ADJUSTMENT These two 2 settings are available from the COMBUSTION LEVEL page Note To obtain optimal results make sure the venting system heat exchanger and exhaust channels are cleaned before performing any setting changes 6 1 6 1 PILOT ADJUST Pilot Settings Adjustment The PILOT SETTINGS ADJUSTEMENT will allow you to modify defa...

Страница 31: ... is excessive and or if the flame is low and almost at the same height at any combustion level You may also want to increase the exhaust fan speed if vent configuration is too restrictive or flame height tends to be high at any combustion level see Appendix C Flame Characteristics 6 1 7 Convection Fan Speed Reduction Optional When the grey fan icon is displayed the convection fan is on default set...

Страница 32: ...atus Page choose the letter icon then select SETUP and MODE Indicates that the stove is in manual mode It will therefore run continuously on the selected setting until it is manually modified turned OFF or if the stove runs out of pellets Indicates that the stove is in thermostat mode The red waves indicate that the thermostat is calling for heat It will heat at the selected combustion level until...

Страница 33: ...t on the thermostat is reached When the ALWAYS OFF pilot cycle is selected the stove will shut down when the temperature set on the thermostat is reached Every time the thermostat will call for heat the stove will need to go through the complete ignition cycle 6 1 9 2 30 Minutes 45 Minutes or 60 Minutes The pilot cycle begins when temperature set on the thermostat is reached It will last 30 45 or ...

Страница 34: ...10 1 Feed and Start Use this option when you start the stove for the first time of the season or after the hopper ran out of pellets The auger will turn for one minute then the stove will automatically start an ignition cycle 6 1 10 2 Purge Screw Use this option to empty the auger at the end of the season When selected the auger will turn for two minutes 6 1 10 3 Add Pellets Use this option to man...

Страница 35: ...he main status page 7 3 Running Out of Pellets If your stove runs out of pellets the fire will slowly go out the convection fan will run until the heat sensor on the exhaust fan reads 115 F The cooling cycle will take a few minutes before all other motors stops When this temperature is reached a warning message NO FUEL will be displayed on the LCD screen To restart the stove wait until all compone...

Страница 36: ...will become very hot If the stove becomes too hot UNIT OVERHEAT code will appear on the LCD screen Before starting the stove again make sure the recommended maintenance has been done properly Press the RESET button and then press the ON OFF icon on the Main Status Page If a UNIT OVERHEAT code occurs twice call you dealer He will be able to give you some advices so this code will not appear again I...

Страница 37: ...will increase cleaning frequency See Section 5 2 1 Proper Fuel for recommended combustibles WARNING FAILURE TO CLEAN AND MAINTAIN THIS STOVE AS INDICATED CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS WARNING NEVER CLEAN WHEN HOT WARNING THE USE OF A DOMESTIC CENTRAL OR COMMERCIAL VACUUM CLEANER TO PERFORM THE MAINTENANCE OF YOUR PELLET STOVE IS NOT RECOMMENDED ASH PARTICLES MAY DAMAGE THE MOTO...

Страница 38: ...affle that are located inside the combustion chamber Use the small metal tabs to remove the panels in the order shown on the following pictures Vacuum heat exchanger tubes Remove the panels in the order shown on the pictures below 8 1 3 Cleaning the Burn Pot Burn pot must stay clean and holes should not be obstructed by combustion residues ashes clinkers 1 2 3 ...

Страница 39: ...ng and pulling it out Once the burn pot is removed make sure all holes are clean Clean thoroughly under the burn pot with an ash vacuum to remove ashes that may have accumulated 3 If necessary clean the air intake channel To reach the air intake channel clean out trap open the ash drawer access door and remove the ash drawer Unscrew the wing nut to open the clean out trap Vacuum the combustion res...

Страница 40: ...rawer of its contents open the ash pan access door by lifting the latch with the drawer handle provided A bracket to hold the drawer handle is located on the right side of the stove at the back 2 Vacuum around the ash drawer and at the bottom of the combustion chamber WARNING ASH PAN MUST BE IN PLACE AND THE ASH PAN ACCESS DOOR MUST BE KEPT CLOSED WHEN THE STOVE IS IN USE ...

Страница 41: ...G DO NOT CLEAN THE GLASS WHILE IT S HOT WARNING DO NOT FORCE STRIKE OR ADOP ANY BEHAVIOUR THAT COULD WEAKEN THE GLASS DOOR WARNING DO NOT OPERATE THE STOVE WITH THE GLASS REMOVED CRACKED OR BROKEN 8 1 7 Replacement of Broken Door Glass Carefully remove any loose pieces of glass from the doorframe Dispose all broken glass properly A broken glass must be replaced with an identical ROBAX ceramic glas...

Страница 42: ...the firebox Therefore the gasket should be inspected periodically making sure to obtain an air tight fit Airtightness can be improved with a simple latch mechanism adjustment To adjust 1 Remove the lock pin by pulling and turning with pliers and turn the handle counter clock wise one turn to increase pressure 2 Re install the lock pin spring pin with a small hammer 8 1 10 Exhaust Channel and Exhau...

Страница 43: ...ny dirt or ash build up in the exhaust channels and exhaust blower housing being careful not to damage the blower s blades Use the scraper provided with the stove to clean heat exchanger outlet Make sure the gaskets are still in good condition replace them if needed ...

Страница 44: ...sible danger 2 If you need assistance call the fire department 3 If possible use a dry chemical fire extinguisher baking soda or sand to control the fire Do not use water as it may cause dangerous vapour explosions 4 Check outside to ensure that sparks and hot embers coming out of the chimney are not igniting any combustible material close by 5 Do not use the stove again until your chimney and sto...

Страница 45: ... section before calling technical support The following sections will help you test each component individually and will also give you many tips in how to solve any problems related to a specific error code NOTE IF YOU NEED TO CONTACT YOUR DEALER OR TECHNICAL SUPPORT MAKE SURE TO HAVE THE MODEL OF YOUR STOVE AND THE SERIAL NUMBER ON HAND THEY CAN BE FOUND ON THE CERTIFICATION LABEL INSIDE THE HOPP...

Страница 46: ... change you will see it right away Page 2 and 3 will give you statistics on how many times you had a specific error code WITH GREEN ICONS Pressure switch is at closed state This is normal state Pressure switch is at opened state This is normal state WITH RED ICONS Pressure switch is at closed state This is abnormal state Pressure switch is at opened state This is abnormal state 9 2 Testing Compone...

Страница 47: ...many suggestions to guide you in resolving them After giving an error code your stove will shut down by itself and start a cool down cycle If you want to start your stove again you will need to press on the button and then on the ON OFF button Your stove will only restart when the cool down cycle is completed NOTE IF AFTER PERFORMING ALL THE POSSIBLE SOLUTIONS MENTIONED IN THE FOLLOWING SECTION YO...

Страница 48: ...se is well installed on the exhaust blower pressure tap and on the white pressure switch tap If not reinstall it The exhaust or combustion blower failed Go to the troubleshooting page on the LCD screen and test the combustion and the exhaust blowers independently see Section 9 2 Testing Components If one of them does not work make sure there is power and that blowers are well connected If they sti...

Страница 49: ...y need to remove the rear panel for an easier access Pull out the auger from the housing Once the auger has been removed make sure the auger is straight his surface is not damaged and there are no burrs or broken welds Remove any foreign material that may have caused the jam Inspect the auger housing for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused...

Страница 50: ...a problem on minimum feed rate or pilot mode Depending on many factors ambient temperature pellet quality etc the heat produced by the stove may not be sufficient to keep the exhaust temperature high enough To resolve the situation increase feed rate see Section 6 1 6 Adjusting the Combustion Level Heat Output The igniter is defective Test the continuity of the igniter with a multimeter If it is g...

Страница 51: ...You may need to remove the rear panel for an easier access Pull out the auger from the housing Once the auger has been removed make sure there are no bent flights burrs or broken welds Remove any foreign material that may have caused the jam Inspect the auger housing for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam Clean the auger housing tho...

Страница 52: ... clean blower housing and make sure blower louvers are not blocked NOTE IF THE CODE APPEARS MORE THAN THREE TIMES THE LCD SCREEN WILL LOCK ITSELF UP AND YOU WILL NEED TO CALL A SERVICE TECHNICIAN TO UNLOCK IT The hopper lid remained open for more than 3 minutes As a security measure the auger stops turning and feeding pellets as soon as the hopper lid opens It will resume normal operation as soon ...

Страница 53: ...d Make sure the venting system meets the criteria in the installation section of this manual as well as the venting system manufacturer s instructions Inadequate fuel is used Remove the burn pot make sure that all openings are clear and check that no ash has filled the tube around the igniter Refer to the maintenance section Also make sure that recommended fuel is used see Section 5 2 1 Proper Fue...

Страница 54: ...54 Eurostar Installation and Operation Manual 10 WIRING DIAGRAM ...

Страница 55: ... 55 11 FUSES ACCESS WARNING UNPLUG THE STOVE BEFORE CHANGING THE FUSES All fuses are located inside the housing of the electronic board the housing is on the back of your stove Unplug your stove and turn the four spring clip to open the housing ...

Страница 56: ...56 Eurostar Installation and Operation Manual 12 COMPONENT LOCATION ...

Страница 57: ...Eurostar Installation and Operation Manual 57 13 EXPLODED VIEW AND REPLACEMENT PARTS ...

Страница 58: ...32 DIA X 1 1 2 LONG 1 9 PL62418 REPLACEMENT GLASS 9 11 64 X 14 11 16 1 10 AC06810 GASKET KIT SELF ADHESIVE BLACK 1 8 X 3 8 1 11 PL64472 HINGE SIDE GLASS RETAINER 1 12 PL64473 HANDLE SIDE GLASS RETAINER 1 13 30124 SCREW 8 32 X 5 16 TRUSS QUADREX ZINC 12 14 SE44132 PELLET IGNITER ASSEMBLY 120 V 1 15 SE64289 BURN POT RECEPTACLE MAINTENANCE ACCESS DOOR 1 16 AC06815 GASKET KIT SELF ROUND BLACK 3 16 1 1...

Страница 59: ...KET KIT 4 5 FT 1 52 99999 BUILD TO ORDER 1 53 99999 BUILD TO ORDER 1 54 44098 HOPPER LID SAFETY SWITCH 1 55 PL64490 HOPPER LID SUPPORT 1 56 SE62421 LCD BRACKET 1 57 SE64358 LCD WITH HOUSING 1 58 PL64358 EUROSTAR TOUCH SCREEN ELECTRONIC BOARD LCD 1 59 30710 SPRING CLIP 4 60 SE64459 PC BOARD WITH HOUSING 1 61 30408 ELECTRONIC BOARD CLIP 4 62 PL64357 MOTHER BOARD 6 OUPUT 1 63 44015 FUSE 5A 250V 1 4 D...

Страница 60: ... MAGNET IN STEEL RECEPTACLE 2 88 SE64373 DOUBLE CAGE BLOWER WITH HOUSING 1 89 AC01325 BLACK SIDE PANELS KIT EUROSTAR 2 89 AC01326 CREME ENAMELED SIDE PANELS KIT EUROSTAR 2 89 AC01327 RED ENAMELED SIDE PANELS KIT EUROSTR 2 90 99999 BUILD TO ORDER 1 91 99999 BUILD TO ORDER 1 92 44038 AUGER GEAR MOTOR 1 RPM 1 93 SE64319 HOPPER AUGER SUPPORT WITH BUSHING AND GASKET 1 94 PL64439 REMOVABLE DRAWER HANDLE...

Страница 61: ...g of a horizontal vent coming out at the back of the stove on a total distance of 8 feet This horizontal run is followed by a tee and a 6 foot vertical rise This type of installation is not acceptable As you can see the vent termination is clearly outside the allowed configuration zone on the chart because the venting system proposed does not have at least one foot of vertical rise for each foot o...

Страница 62: ...ptable The installation end should be within the allowable configuration zone on the chart since it would have at least one foot of vertical rise for each foot of horizontal run Furthermore the total vertical rise would be at least 3 foot high WARNING To reduce the risk of smoke spillage there should always be at least one foot of vertical rise for each foot of horizontal run In all cases at least...

Страница 63: ...ft side configuration extend the rail with the LCD support E in order to access the two screws A which secures the rail mechanism to the mounting bracket Remove the screws rotate the rail 180 and reassemble the rail to the mounting bracket using the screws previously removed Step 2 Remove the screws C located on the top edge of the back of the stove Secure the mounting bracket B in place with the ...

Страница 64: ...Operation Manual Step 3 Take the Telco black wire D which is located on the rear bottom panel and plug it into the back of the LCD touch screen interface receptacle Step 4 Finally secure the LCD touch screen housing F on the rail E ...

Страница 65: ...mum efficiency Fire with too much air A small blow torch flame as in the image below is a result of too much oxygen being supplied to the fire This causes the flame to be very short with a bright yellow to almost white flame look This pattern does not allow optimum heat transfer to the exchanger therefore reduces convection efficiency Depending on the quality of the pellets there are usually more ...

Страница 66: ...ir flow through the system The possible causes are either a lack of oxygen to the fire high moisture content pellet obstructed channel or vent This situation will lead to excessive black soot accumulation on the baffle and the glass To rectify this condition make sure the stove and the vent system is clean the pellet being used is dry and increase combustion air flow if necessary ...

Страница 67: ...codes Install the thermostat in a location that provides good airflow characteristics and avoid areas behind doors near corners air vents direct sunlight or heat generating devices It should also be located at least 15 to 20 feet from the stove To prevent cycling you should avoid installing the thermostat on a poorly insulated outside wall or directly in front of the stove Wired thermostat Before ...

Страница 68: ...s thermostat or a hand held thermostatic remote control connect the two thermostat wires to the terminal block located at the rear on the right hand side of the stove while facing it If the receiver wires are equipped with quick connect terminals you can connect them directly to the stove s wiring harness To do so open the right hand side decorative panels and disconnect the two 2 harness wires at...

Страница 69: ...FOR MOBILE HOME INSTALLATION IT IS MANDATORY TO CONNECT THE STOVE TO AN OUTSIDE COMBUSTION AIR SOURCE SEE APPENDIX F When installed in a mobile home the stove must be anchored to the floor with two screws Use the two holes located for this purpose on each side of the pedestal as shown on the following image ...

Страница 70: ...stalled When doing so it is preferable to choose a wall which is not exposed to dominant winds depending on the conditions surrounding your house An insulated 3 inside diameter metallic pipe either flexible or rigid must be attached to the fresh air intake A A rodent guard minimum wire mesh must be used at the termination All connections must be secured and airtight by either using the appropriate...

Страница 71: ...om an outside wall behind the stove NOTE The stove exhaust blower produces a negative pressure in the room It draws air from the inside to the outside In the same way other appliances can also create a bigger negative pressure In this case as the air naturally flows from high pressure point to low pressure point the bigger negative pressure may draw the smoke from the inside of the stove into the ...

Страница 72: ...t All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts T...

Отзывы: