28
Eurostar Installation and Operation Manual
Description of each main status page icon:
Indicates that the stove is in the manual mode. It will therefore run
continuously on the selected setting until it is manually modified, turned
OFF or if the stove runs out of pellets (see
Section 6.1.8
Selecting
Manual or Thermostat Mode
).
Indicates that the stove is in the thermostat mode. The red waves indicate
that the thermostat is calling for heat. The waves will disappear once the
thermostat has reached room temperature setting (see
Section 6.1.8
Selecting Manual or Thermostat Mode
).
Indicates the exhaust temperature. If temperature is below 115
⁰
F, the
numeric value will disappear and “COOL” will be displayed.
Selecting the flame icon will bring you to the heat control scroll bar. Moving
the cursor to the left will reduce the feed of pellets therefore produce less
heat and moving it to the right will increase the feed of pellets which will
produce more heat (see
Section 6.1.6
Adjusting the Combustion Level
(Heat Output)
).
Indicates that the stove is
“Off”.
Indicates that the stove is either
“On” in manual mode or calling for
heat in thermostat mode.
Indicates that the stove is in
thermostat mode, in pilot
cycle waiting for heat
calling.
Indicates that the stove is in
thermostat mode but not calling
for heat and pilot cycle is
completed.
Selecting the letter icon will display a menu screen where you can access
the following pages: Set-up, Trouble shoot, Statistics and Program (see
Section 6.1.2
Configuration and Operation Diagram
).
Selecting the grey auger icon will display the auger option menu. Once
auger option is selected auger icon will show a red arrow and will blink until
the end of the chosen option (see
Section 6.1.10
Filling or Purging
Auger Housing
).
The grey fan icon indicates that the convection fan is on default setting.
The grey fan icon with red arrows indicates that fan speed default setting
has been reduced with the optional fan speed scroll bar (see
Section 6.1.7
Convection Fan Speed Reduction (Optional)
).
Indicates the selected pilot cycle. Once selected, one of the following
cycles, (30min, 45min, 60min, Always On or Always Off) will display under
the hourglass icon (see
Section 6.1.9
Selecting The Pilot Cycle
). Default
setting is “Always Off”.
Indicates that unusual cycle has been detected. When this occurs, the
envelope icon will be displayed in replacement of the convection fan icon.
Press on the envelope to read the warning message.
135ºF
COOL