18
Eurostar Installation and Operation Manual
4.5.2 Through Wall Installation (Main Floor or Basement)
1. Position stove following clearances given in
Section 3,
Clearances to Combustible Material
and following vent manufacturer’s instructions. Then locate the position of the exhaust pipe in
the wall.
2. Install wall thimble as per vent manufacturer’s instructions.
3. Attach enough piping length to go through the wall thimble and extend at least 6 inches beyond
the exterior wall.
4. Attach cap and seal outside wall thimbles with high temperature waterproof silicone sealant.
CAUTION: TO REDUCE THE RISK OF SMOKE SPILLAGE THERE SHOULD ALWAYS BE AT
LEAST ONE FOOT OF VERTICAL RISE FOR EACH FOOT OF HORIZONTAL RUN. IN ALL
CASES, AT LEAST 3 FEET OF VERTICAL RISE IS NEEDED.
WARNING: TERMINATION SHOULD NOT BE LOCATED SO THAT HOT EXHAUST GASES
CAN BE A HAZARD. EXHAUST GASES CAN REACH TEMPERATURES OF 500ºF AND
CAUSE SERIOUS BURNS. SEE SECTION 4.4.1 PERMITTED TERMINATION LOCATION