Installation
Proline Promag H 100
22
Hauser
1
3
2
4
2
A0002651
8
Installing grounding rings
1
Hexagonal-headed bolts of process connection
2
O-ring seals
3
Grounding ring or plastic disk (spacer)
4
Sensor
1. Release the 4 or 6 hexagonal-headed bolts (1) and remove the process connection from
the sensor (4).
2. Remove the plastic disk (3), along with the two O-ring seals (2), from the process
connection.
3. Place the first O-ring seal (2) back into the groove of the process connection.
4. Fit the metal grounding ring (3) in the process connection as illustrated.
5. Place the second O-ring seal (2) into the groove of the grounding ring.
6. Mount the process connection back on the sensor. In doing so, make sure you comply
with the max. screw tightening torques for lubricated threads: 7 Nm (5.2 lbf ft)