Appendix
Liquisys M CCM223/253
110
Hauser
12
Appendix
Operating matrix CCM223/253 - versions EK and ES
a0002633-en
C
A6
A2
A1
A3
A4
A5
A
B
Z
O332
B5
O333
B2
O3(3)
B3
O331
B4
O3(2)
O321
O
O1
O2
O3(1)
O311
O312
O313
C15
C12
C13
C14
C11
F2
F1
F
F5
F3
F4
F6
Z5
Z1
Z2
Z3
Z4
Z6
C15
C14
C15
Only display switchover!
CURRENT INPUT
SETUP 2
SETUP 1
CURRENT OUTPUT
1st error displayed
(if present)
Other errors are
displayed
(up to max. 10 errors)
Meas. value display
Current input in %
Meas. value display
Current input in mA
Controller switch-off
by sample stream
INS
Off;
Select display unit
; ppm; ppb
mg/l
Cont. switch-off
by current input
Input
Off;
Select current range
0–20 mA
4–20 mA;
Enter 0/4 mA value
0 ... 20 (5) mg/l
0 ... 50 °C
0.00;
0 °C;
Enter 20 mA value
0 ... 20 (5) mg/l
0 ... 50 °C
2.0 (0.5);
50 °C;
lin = linear
PH compensation
Manu
Off;
Sw.-off direction
for current input
High
Low;
Select sensor
141; 240; 241;
963; 120
140;
Select current output
Output2
Output1;
Enter
DPD value
Value of last cal.
Delay for controller
switch-off sam. stream
0 ... 2000 s
0 s
Delay for cont.
switch-off curr. input
0 ... 2000 s
0 s
Tab = Table
sim = Simulation
Manual
pH compensation
pH 4.00 ... 9.00
last comp. value
Delay for contr.
swi.-on sam. stream
0 ... 2000 s
0 s
Delay for cont.
sw.-on current input
0 ... 2000 s
0 s
Enter simulation
0 ... 22.0 mA
val.
current value
Select table
options
edit
read
Enter no. of
table pairs
1 ... 10
1
Select
table pairs
1 ... no. Table pair
asign
1
Enter correct
process temperature
0 ... 50 °C
current meas. value
Select
digital input 1
Clean trig.
ext.Hold
Sw.-off limit value
for current input
0 ... 100%
50%
Enter temperature
difference (offset)
–5.0 ... + 5.0 °C
current offset
MEAS. VALUE
DISPLAY
with
TEMPERATURE
READING
in °C
Zero calibration
(only if A1 = 120 or 963)
yes
no;
Calibration status
is displayed
Exxx
o.k.
Store
calibration
no; new
yes;
Slope is
displayed
min. 25% (3%)
max. 500%
100%
CALIBRAT
Cl2 / ClO2
ALARM
Select contact type
=
Latch = latching c.
Momen
momentary c.
Select unit of alarm
delay
s
min;
Define
error current
2.4 mA
22 mA;
Select error number
1 ... 255
1
Enable alarm
contact
no
yes;
Alarm delay
0 ... 2000 min (s)
(dep. on F2)
0 min (s)
Feedforward control
to PID cont.
lin = linear
Off;
Meas. value display
Temperature reading in °F
Meas. value display
no temp. display
Meas. value display
Sensor current in nA
Edit:
Code
22
Read:
any
code
Edit:
Code
22
Read:
any
code
Select meas. unit for
2nd current output
; mg/l; ppm; ppb; Contr
°C
Zero calibration
yes
(only if A1 = 120)
no;
Calibration status is
displayed
Exxx
o.k.
Store calibration
result
no; new
yes;
CALIBRATION
zero
(CCS120)
Содержание Liquisys M CCM223
Страница 109: ...Liquisys M CCM223 253 Technical data Endress Hauser 109...
Страница 116: ...Appendix Liquisys M CCM223 253 116 Endress Hauser a0002639 en...
Страница 120: ...Appendix Liquisys M CCM223 253 120 Endress Hauser...
Страница 123: ...Liquisys M CCM223 253 Endress Hauser 123...
Страница 124: ...www addresses endress com 71212626...