Installation
Levelflex M FMP40 with HART/4...20 mA
22
Hauser
3.6.5
Replacing a displacement system in an existing displacer
chamber
The Levelflex M is a perfect replacement for a conventional displacer system in an existing displacer
chamber. In addition to the DIN and ANSI flanges, which are available as standard,
Hauser also offers flanges that suit Fischer and Masoneilan displacer chamber (special
product) for this purpose. Thanks to menu-guided local operation, commissioning the Levelflex M
only takes a few minutes. Replacement is also possible when partially filled, and wet calibration is
not required.
Your benefits:
• No moving parts, thus zero-maintenance operation.
• Not sensitive to process influences such as temperature, density, turbulence and vibrations.
• The rod probes can be shortened or replaced easily. In this way, the probe can be easily adjusted
on site.
L00-FMP4xIxx-17-00-00-en-002
Planning instructions:
• In normal cases, use a rod probe. When installing into a metal displacement housing up to
150 mm (100 mm for interface), you have all the advantages of a coax probe.
• It must be ensured that the probe does not come into contact with the side wall. Where necessary,
use a centering disk at the lower end of the probe (
• A centering disk must be adapted as accurately as possible to the internal diameter of the displacer
chamber to also ensure perfect operation in the area of the probe end.
Additional information on interface measurement
• The pipe may not exhibit any steps in diameter. Use the coax probe where necessary.
• In the case of rod probes, it must be ensured that the probe does not come into contact with the
wall. If necessary, use a centering disk at the end of the probe.
!
Note!
A plastic centering disk has to be used for interface measurement, see Accessories
displacer chamber flange
Содержание Levelflex M FMP40
Страница 4: ...Brief overview Levelflex M FMP40 with HART 4 20 mA 4 Endress Hauser...
Страница 87: ...Levelflex M FMP40 with HART 4 20 mA Appendix Endress Hauser 87...
Страница 88: ...Appendix Levelflex M FMP40 with HART 4 20 mA 88 Endress Hauser...
Страница 90: ...Levelflex M FMP40 with HART 4 20 mA Index 90 Endress Hauser...
Страница 92: ...www endress com worldwide BA363F 00 en 03 09 No 71074941 CCS FM SGML 6 0 ProMoDo 71074941...