Deltatop DP71B, DP72B, DP73B
Installation
Hauser
21
3.9
Installation steps for the welding flange version
P01-DP7xxxx-17-xx-xx-xx-003
A: Without end support B: With end support
1: Sensor flange 2: Sensor 3: Nut 4: Stud 5: Gasket 6: Mounting flange and weld coupling
7: Weld coupling 8: Weld cap
!
Note!
• Do the pipe dimensions (inner diameter, wall thickness, thickness of insulation) match the data
of the order and the specifications of the device?
• Do the medium properties and process data match the specifications on the supplied calculation
sheet?
1.
Completely depressurize and drain the pipe prior to installing the Deltatop.
2.
Drill a hole with the diameter D1 into the pipe.
3.
Loosely bolt the sensor, gasket and mounting flange together (hand-tight).
4.
Insert the assembly into the pipe. Align the head of the sensor so that the arrow labeled "flow"
on the head is in the direction of the flow to within 3°.
5.
Tack-weld the mounting flange into position by using the appropriate weld gap (typically 1/
16" (1.5 mm)).
!
Note!
The bolt holes of the flange must be at 45° angles (for four holes) or 22.5° angles (for eight
holes) to the pipe axis.
P01-DP6xxxx-17-xx-xx-xx-003
D
1
D
1
D
1
D
1
D
1
D
1
A
B
1
1
2
2
4
4
5
5
3
3
7
8
6
6
Probe
Diameter of the hole (D1)
DP71B
1/2" (13 mm)
DP72B
1" (25 mm)
DP73B
1-1/2" (38 mm)
4
5
°
22
,
5°