Deltatop DP71B, DP72B, DP73B
Installation
Hauser
31
3.14
Installation steps for the flowtap welding flange version
with a spindle
P01-DP7xxxxx-17-xx-xx-xx-008
A: Single rod B: Double rod
1: Drive nut 2: Sensor plate 3: Sensor bushing 4: Packing bolts 5: Packing gland 6: Threaded bush 7: Jam nut
8: Access nipple 9: Threaded drive rod 10: Stop nut 11: Sensor 12: Studs and nuts 13: Gasket 14: Access valve
15: Mounting flange
!
Note!
• Do the pipe dimensions (inner diameter, wall thickness, thickness of insulation) match the data
of the order and the specifications of the device?
• Do the medium properties and process data match the specifications on the supplied calculation
sheet?
1.
Completely depressurize and drain the pipe prior to installing the Deltatop.
2.
Drill a hole with the diameter D1 into the pipe.
3.
Tack-weld the welding socket into position by using the appropriate weld gap.typically 1/16"
(1.5 mm)).
!
Note!
The bolt holes of the flange must be at 45° angles (for four holes) or 22.5° angles (for eight
holes) to the pipe axis.
P01-DP6xxxx-17-xx-xx-xx-003
4.
Bolt the access valve to the mounting flange using the gasket, studs and nuts provided.
A
(
B
)
(
B
)
1
2
3
4
5
6
7
8
9
11
1
0
1
2
1
2
1
3
1
3
1
4
1
5
D
1
Probe
Diameter of the hole (D1)
DP71B
1/2" (13 mm)
DP72B
1" (25 mm)
DP73B
1-1/2" (38 mm)
4
5°
22
,