Operation
3-9
Part 1102771A
E
2010 Nordson Corporation
Help Codes
The Help icon in the Function/Help display lights if a problem occurs.
Display Codes
Clear Codes
Figure 3-9
Displaying and Clearing Help Codes
Press the
Help
button to display the Help codes. The controller
retains the last 5 codes in memory. Rotate the knob to scroll through the
codes. The display blanks if there is no activity for 5 seconds.
To clear the Help codes, scroll through them until
CLr
is displayed,
then press the
Enter
button. The Help icon stays lit until the controller
clears the codes.
Refer to
Section 4, Troubleshooting
for help code troubleshooting, general
system troubleshooting, resistance and continuity tests, and system wiring
diagrams.
Maintenance Timer, Configuration, and Versions
Press the
View
button and turn the rotary knob to view, in the
following order: Maintenance hours, Total hours, Gun Controller (GC), Gun
Display (Gd), iFlow Module (FL) software versions and Hardware version
(Hd). The Maintenance hour timer is set through the Controller
Configuration on page 3-17. Total hours cannot be reset.
The Help icon lights if the maintenance timer is set and runs out.
To reset the maintenance timer, press the
View
button.
The Timer icon lights when the maintenance hours are displayed.
While they are displayed, press the
Enter
button.
Figure 3-10 Displaying Maintenance Hours
Содержание 1102771A
Страница 6: ...Table of Contents iv Part 1102771A E 2010 Nordson Corporation...
Страница 10: ...Safety 1 4 Part 1102771A E 2010 Nordson Corporation...
Страница 42: ...Operation 3 20 Part 1102771A E 2010 Nordson Corporation...
Страница 56: ...Troubleshooting 4 14 Part 1102771A E 2010 Nordson Corporation...
Страница 76: ...Repair 5 20 Part 1102771A E 2010 Nordson Corporation...
Страница 92: ......
Страница 93: ......