Operation
3-14
Part 1102771A
E
2010 Nordson Corporation
Smart Flow Mode Settings
(contd)
Increase flow,
no change in velocity
Max Flow
Increase velocity,
no change in flow
50% Flow Air % Setpoint
3.00 Total Flow Setpoint
Max Velocity
Figure 3-17 Reading the Smart Flow Tables
Setting Smart Flow Setpoints
To set flow air % or total flow
:
1. Press the % or
button. The LED on the selected button lights.
2. Turn the knob to increase or decrease the setpoint. The setpoint is
automatically saved if it does not change for 3 seconds or when any
button is pressed.
NOTE:
If Total Flow is set to zero, the Flow Air % setpoint cannot be set to
anything but zero, and powder cannot be sprayed. To set Flow Air %, set
Total Flow to a value greater than zero.
S
When the spray gun is not triggered the setpoints are displayed.
S
When the spray gun is triggered the displays show actual flows.
Flow Air %
Total Flow Air in M
3
/HR or SCFM
Figure 3-18 Smart Flow Mode -- Flow Air % or Total Flow