Operation
3-11
Part 1102771A
E
2010 Nordson Corporation
Custom Mode
Custom Mode
is the factory default mode. In this mode, both kV and
A
can be adjusted independently. The STD and AFC icons are not displayed.
NOTE:
Refer to
Controller Configuration
on page 3-17 for a list of the mode
defaults and configuration instructions.
1. To set or change the kV setpoint, press the KV button. The button LED
lights to show that kV is selected.
2. Turn the rotary knob to increase or decrease the kV setpoint. The
setpoint is automatically saved if it does not change for 3 seconds, or
when any button is pressed.
3. To set or change the
A setpoint, press the
A button. The button LED
lights to indicate that
A is selected.
4. Turn the rotary knob to increase or decrease the
A setpoint. The
setpoint is automatically saved if it does not change for 3 seconds, or
when any button is pressed.
NOTE:
The default
A range is 10--50
A. The limits of the range can be
adjusted. Refer to
Controller Configuration
on page 3-17.
S
When the gun is not triggered the KV and
A setpoints are displayed.
S
When the gun is triggered the actual KV and
A outputs are displayed.
Custom Mode -- Preset Setpoints
Custom Mode -- Gun Triggered
Figure 3-13 Custom Mode -- Setpoints and Gun Triggered Displays
Classic Mode
To use Classic mode, the controller must be configured for it. Refer to
Controller Configuration
on page 3-17.
In Classic mode you can choose to control kV (STD) output or
A (AFC)
output, but not both at the same time.
Classic Standard (STD) Mode
Use the Standard mode to set kV. In Standard mode you cannot set
A.
1. To set the kV setpoint, press the KV button. The button LED lights to
show that kV is selected.
Содержание 1102771A
Страница 6: ...Table of Contents iv Part 1102771A E 2010 Nordson Corporation...
Страница 10: ...Safety 1 4 Part 1102771A E 2010 Nordson Corporation...
Страница 42: ...Operation 3 20 Part 1102771A E 2010 Nordson Corporation...
Страница 56: ...Troubleshooting 4 14 Part 1102771A E 2010 Nordson Corporation...
Страница 76: ...Repair 5 20 Part 1102771A E 2010 Nordson Corporation...
Страница 92: ......
Страница 93: ......