System Setup
2-11
Part 1102771A
E
2010 Nordson Corporation
System Air and Electrical Connections
System Air Supply
See Figure 2-11. Connect 10-mm air tubing from your compressed air
supply to the system air filter in the power unit cabinet. The air supply
pressure should be 6.0--7.6 bar (87--110 psi).
An optional input air kit with connectors, couplings, and 20 ft of 10 mm
tubing is available. Refer to the
Parts
section for the kit contents and
ordering information.
NOTE:
Compressed air should be supplied from an air drop equipped with
a self-relieving shutoff valve. The air must be clean and dry. A refrigerant
or desiccant-type air drier and air filter/separators are recommended.
10-mm
Air Tubing
Air Filter
Regulator
Figure 2-11 System Air Supply Connection
Содержание 1102771A
Страница 6: ...Table of Contents iv Part 1102771A E 2010 Nordson Corporation...
Страница 10: ...Safety 1 4 Part 1102771A E 2010 Nordson Corporation...
Страница 42: ...Operation 3 20 Part 1102771A E 2010 Nordson Corporation...
Страница 56: ...Troubleshooting 4 14 Part 1102771A E 2010 Nordson Corporation...
Страница 76: ...Repair 5 20 Part 1102771A E 2010 Nordson Corporation...
Страница 92: ......
Страница 93: ......