Operation
3-5
Part 1102771A
E
2010 Nordson Corporation
NOTE:
Re-install the electrode if it comes out of the powder outlet tube.
4. Install a new nozzle on the electrode assembly. The nozzle is keyed to
the electrode assembly. Do not bend the electrode wire.
5. Screw the nozzle nut onto the gun body clockwise until finger-tight.
Nozzle Nut
Flat Spray Nozzle
Electrode Assembly
Figure 3-4
Changing a Flat Spray Nozzle
Changing Deflectors or Conical Nozzles
WARNING:
Release the spray gun trigger, turn off the interface, and
ground the electrode before performing this procedure. Failure to observe
this warning could result in a severe electrical shock.
1. Purge the spray gun and press the standby button to turn off the
interface and prevent accidental gun triggering.
2. Gently pull the deflector off the electrode assembly. If only changing the
deflector, install the new one on the electrode assembly, being careful
not to bend the electrode wire.
3. To change the entire nozzle, unscrew the nozzle nut counterclockwise.
4. Pull the conical nozzle off the electrode assembly.
NOTE:
If the electrode assembly comes out of the powder outlet tube,
re-install it.
5. Install a new conical nozzle on the electrode assembly. The nozzle is
keyed to the electrode assembly.
6. Screw the nozzle nut onto the gun body clockwise until finger-tight.
7. Install a new deflector on the electrode assembly. Do not bend the
electrode wire.
Deflector
Nozzle Nut
Nozzle
Electrode Holder
Electrode
Assembly
Figure 3-5
Changing a Conical Nozzle
Содержание 1102771A
Страница 6: ...Table of Contents iv Part 1102771A E 2010 Nordson Corporation...
Страница 10: ...Safety 1 4 Part 1102771A E 2010 Nordson Corporation...
Страница 42: ...Operation 3 20 Part 1102771A E 2010 Nordson Corporation...
Страница 56: ...Troubleshooting 4 14 Part 1102771A E 2010 Nordson Corporation...
Страница 76: ...Repair 5 20 Part 1102771A E 2010 Nordson Corporation...
Страница 92: ......
Страница 93: ......