Function parameter schedule graph
26
function selection
1: Multi-step speed control terminal 1
2: Multi-step speed control terminal 2
3: Multi-step speed control terminal 3
4: Multi-step speed control terminal 4
5: External forward run jog control
6: External reverse run jog control
7: Accel / Decel time selecting terminal 1
8: Accel / Decel time selecting terminal 2
9: Accel / Decel time selecting terminal 3
10: External device failure input
11: External restoration input
12: Free stop input
13: External stop command
14: stop DC braking input command DB
15: Inverter run prohibition
16: Frequency increasing command( UP)
17: frequency descending command( DOWN)
18: Accel /Decel prohibited command
19: Three-wire run control
20: Closed-loop ineffective
21: PLC ineffective
22: Simple PLC pause command
23: PLC stop status restoration
24: Frequency provision channel selection 1
25: Frequency provision channel selection 2
26: Frequency provision channel selection 3
27: Frequency switched to CCI
28: Command switched to terminal
29: Run command channel selection 1
30: Run command channel selection 2
31: Run command channel selection 3
32: Traverse running
33: External interruption input
34: interior counter clearing end
35: interior counter triggering end
36: Interior timer clearing end
37: interior timer triggering end
38: Reserved
39: Reserved
40: forward running FWD terminal
41: reverse running REV terminal
42: Reserved
F5.01
Input terminal X2
function selection
Same as F5.00
×
F5.02 Reserved
F5.03 Reserved
F5.04 Reserved
F5.05 Reserved
F5.06
Input terminal FWD
function
Same as F5.00
40
×
F5.07
Input terminal REV
function
Same as F5.00
41
×