![ENC EDS300 Series Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/enc/eds300-series/eds300-series_manual_2405767046.webp)
Modbus Communication Protocol
42
7.7.2 Stop 1# inverter running
Data
Field
Slave
Inverter
Addr
ess
Comman
d
code
Register
addr
ess
High byte
Register
addr
ess
Low byte
Data
High byte
Data
Low byte
CRC
low bit
CRC
high bit
Host
command
frame
01 06 20 00 00 06 02 08
Slave
respond
frame
01 06 20 00 00 06 02 08
7.7.3 Set 1# inverter specified value to 50Hz
Data Field
Slave
Inverter
Addr
ess
Comman
d
code
Register
addr
ess
High byte
Register
addr
ess
Low byte
Data
High byte
Data
Low byte
CRC Low
bit
CRC Hig
h bit
Host
command
frame
01 06 20 01 13 88 DE 9C
Slave
respond
frame
01 06 20 01 13 88 DE 9C
7.7.4 Read 1# inverter running state
Data Fiel
slave Inver
ter
Addr
ess
Comman
d
code
Register
addr
ess
High byte
Register
addr
ess
Low byte
Data
High byte
Data
Low byte
CRC
low bit
CRC
high bit
Host
command
frame
01 03 21 00 00 01 8E 36
Slave respond
frame
01 03
(Number of
respond value
bytes ) 02
00 00 B8 44
ENC